Alignment and Adjustment
4-2-3 CVF Adjustment
Notes :
1. After each adjustment step is completed, OSD shows "OK".
2. EEPROM(ICV02) stores confirmed adjustment value of each adjustment step.
3. After finishing the adjustment, reset the main power source (OFF-ON) to memorize the adjustment data
in EEPROM.
4. Remote controller is used as a CVF adjust tool.
4-2-3 (a) PREPARATION
1. How to get into the CVF adjust mode.
STEP2
1. Connect the power source (battery/DC
cable).
2. Set the mode switch of the camcorder to
"PLAYER" position.
3. Set OSD on state.
4. Press and hold the "EJECT" button and
"PLAY/STILL" button on the camcorder at
the same time for more than 5 seconds.
Then unit goes into service mode.
Note : When XX XX is shown in service adjustment procedures, this indicates variable values.
4-28
STEP1
STEP3
PLAY/STILL
EJECT
Short the two lands on the CVF PCB by sol-
der to Ground. (They are displayed on page
4-31)
MONITOR OSD shows "8. PLL EPR XX.
EVR XX". Then CVF adjustment mode has
been activated successfully.
8 PLL
EPR : XX
MODE DOWN
MODE UP
Confirm
DATA UP
DATA DOWN
EVR : XX