Pcbs - Daikin 3MWKS80LV1 Service Manual

Removal procedure
Table of Contents

Advertisement

Outdoor Unit
1.4

PCBs

Warning
Step
1. Remove the electrical box
cover.
1
Peel off the filament
tape.
2
Unfasten the 4 hooks
and remove the
electrical box cover.
2. Remove the filter PCB.
1
Disconnect the
connector [S401].
18
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Hook
Filament tape
(R13681)
Hook
(R13682)
1
2
3
L
N
A
SUPPLY
POWER
2
1
2
1
3
C
B
[S401]
Points
The hooks are marked with
.
[S401]: to main PCB
3
(R13683)
Removal Procedure
Si121557E
(R6427)

Hide quick links: