Electrical Box - Daikin 3MWKS80LV1 Service Manual

Removal procedure
Table of Contents

Advertisement

Outdoor Unit
1.3

Electrical Box

Warning
Step
1
Disconnect the
connector [S70].
2
Release the fan motor
lead wire from the 5
hooks.
3
Disconnect the
connectors for the
electronic expansion
valve coils [S20], [S21],
[S22].
Pull out the clamp.
12
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
[S20] [S21] [S22]
Clamp
[S70]
(R13662)
Fan motor
lead wire
(R13663)
(R15741)
Si121557E
Points
[S70]: fan motor
: When reassembling, do not
use these 2 hooks.
[S20] (white): room A
[S21] (red) : room B
[S22] (blue) : room C
When reassembling, insert
the clamps into the small
holes as below.
Electronic expansion
valve coils
Gas pipe thermistors
Overload protector
and high pressure
Thermistor
switch
ASSY
(R13762)
Removal Procedure