The following intervals apply to normal operating
conditions only. If your daily working time is longer
or operating conditions are difficult (very dusty work
area, etc.), shorten the specified intervals accord‐
ingly.
Cooling inlet
Spark arresting screen in
muffler
All accessible screws and
nuts (not adjusting
screws)
Antivibration elements
Cutting blades
Gearbox lubrication
Safety labels
1)
STIHL recommends an authorized STIHL servicing dealer.
18
Replace after every 100
operating hours
Visual inspection
Clean
Check if installed
1)
Check or replace
Retighten
Visual inspection
Have replaced by serv‐
1)
icing dealer
Clean
1)
Sharpen
Visual inspection
Have replaced by serv‐
1)
icing dealer
commercial use only –
check every 25 hours of
operation and replenish
with STIHL gear lubri‐
cant if necessary
Replace
X
X
X
X
X
15 Maintenance and Care
X
X
X
X
X
0458-447-8321-D
X
X
X