5.3. FLASH Button Notes for Service: The flash time can be back to the default value by talking off the battery and leave the unit for about 3 minutes.
6. DISASSEMBLY INSTRUCTIONS Shown in Fig —. To remove —. Remove —. Lower Cabinet Screws (2.6 × 12).........(A) × 5 FFC and Solder Main P.C. Board Main P.C. Board CPU P.C. Board CPU P.C. Board 7. TROUBLESHOOTING GUIDE Make sure batteries are installed for proper operation before troubleshooting. 7.1.
10. TERMINAL FUNCTION 1. SCL SCL terminal is a serial lock input terminal and used for TX/RX control between master and slave. 2. SDA SDA terminal is an input/output terminal and transfers the address sent from the master device to slave and mutual data. SDA output circuit employs the open drain, therefore the pull-up resistor is requ Terminal ired.
When the bell signal is input between T/R, the signal is outputted at the speaker via the following path: Tel line R1/C1 Pin 1 of IC2/Pin 8 of IC2 Pin 5 of IC2 Ringer 11.2. Line Interface In talk mode, SW101 becomes ON and Q104 base becomes High, causing Q104 and Q102 to turn on and line loop is established.
Page 19
11.4. Initializing Circuit 11.4.1. Function: This circuit is used to initialize the CPU when the batteries are installed. 11.4.2. Circuit operation: When the batteries are inserted into the unit, the voltage is regulated by IC302 and power is supplied to the CPU. The unit starts operating soon after the voltage goes beyond the point A in the voltage diagram.
11.5. Caller ID Detect Circuit 11.5.1. Function (FSK signal) The caller ID is a chargeable ID that the user of telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
11.5.2. Circuit operation: Caller ID Caller ID signal is sent through the following path: TEL Line C551,C552 R551,R552 Pin 87,88 of IC801 12. BLOCK DIAGRAM 12.1. IC801...
Page 23
12.2. CPU DATA (IC801) 12.3. RINGER IC (IC2)
SCK terminal is input terminal of Serial Clock to control transmit and receipt between Master and Slave. 2. SDA SDA terminal is input terminal, to forward the address and the mutual data between Master Device and Slave Device the mutual. This terminal needs the pull-up resistance external because output circuit of SDA uses Open Drain.
Be certain each pin is located over the correct pad on the PCB 2. Apply flux to all of the pins on the IC. 3. Being careful to not unsolder the tack points, slide the soldering iron along the tips of the pins while feeding enough solder to the tip so that it flows under the pins as they are heated.
17. REPLACEMENT PARTS LIST Notes: 1. RTL (Retention Time Limited) The marking (RTL) indicates that the Retention Time is limited for this item. After the discontinuation of this assembly in production, the item will continue to be available for a specific period of time. The retention period of availability is dependant on the type of assembly, and in accordance with the laws governing parts and product retention.
Page 31
17.1. Unit 17.1.1. Cabinet and Electrical Parts Ref. No. Part No. Part Name & Description Remarks PQKM10569V1 CABINET BODY PS-HB PQBH10033Z1 BUTTON, HOOK ABS-HB L0DDFD000002 BUZZER PQSX10218X KEYBOARD SWITCH, 19 KEY PQJE10124Z CONNECTOR, FFC PQKF10572W1 CABINET COVER PS-HB PQKL10047Z1 STAND, WALL MOUNT ABS-HB PQGT15626Z NAME PLATE...
parts be used for the critical components in the shaded areas of the schematic. 18.1. Memo 19. SCHEMATIC DIAGRAM 19.1. Main P.C. Board 19.2. CPU P.C. Board 20. CIRCUIT BOARD 20.1. Main P.C. Board 20.1.1. Component View 20.1.2. Flow Solder Side View 20.2.