Summary of Contents for Agilent Technologies 4263B
Page 1
All manuals and user guides at all-guides.com Agilent 4263B LCR Meter User's Guide Agilent Part No. 04263-90022 Printed in JAP AN December 2000 Fourth Edition...
All manuals and user guides at all-guides.com Preparation for Use In This Chapter Power Requirements LINE Voltage LINE Frequency Power Consumption To Set Power LINE Voltage Preparation for Use...
Page 8
All manuals and user guides at all-guides.com 4263B Table 1-1. Line Voltage Selection Voltage Selector Line Voltage Required Fuse Preparation for Use...
All manuals and user guides at all-guides.com 4263B Resetting 4263B to its Default Settings Connecting Test Fixture Figure 2-1. Connecting a Test Fixture Operating the 4263B...
Page 13
All manuals and user guides at all-guides.com 4263B Setting the Cable Length 0 m 1 m 2 m Selectting the Measurement Parameter Operating the 4263B...
Page 14
All manuals and user guides at all-guides.com 4263B Setting the Test Signal Frequency Setting the Test Signal Level Operating the 4263B...
Page 15
All manuals and user guides at all-guides.com 4263B Setting the DC Bias Source Voltage Selecting the Measurement Time Mode Meas Time Setting the Averaging Rate Operating the 4263B...
All manuals and user guides at all-guides.com 4263B Selecting the Measurement Range Auto Range mode |Automatically Selecting the Optimum Measurement Range Hold Range Hold Range mode|Selecting the Measurement Range of Your Choice Operating the 4263B...
Page 17
All manuals and user guides at all-guides.com 4263B Selecting the Trigger Mode Trigger Setting the Trigger Delay Time Operating the 4263B...
Page 18
All manuals and user guides at all-guides.com 4263B Performing the OPEN Correction |Canceling the stray admittance in parallel with the DUT Openmeas Open Correction Complete Out Of Limit Operating the 4263B...
Page 19
All manuals and user guides at all-guides.com 4263B Performing the SHORT Correction |Canceling the residual impedance in series with the DUT Shortmeas Short Correction Complete Out Of Limit Operating the 4263B...
All manuals and user guides at all-guides.com 4263B Using the Comparator Function Setting the Limit Values Starting the Sort Comptr On HIGH IN HIGH 2-10 Operating the 4263B...
Page 21
All manuals and user guides at all-guides.com 4263B Using the Contact Check Function |Monitoring the connection of test electrodes and DUT Cont Chk N.C. Using the Deviation Measurement Function Setting the Deviation Reference Values 1RefEnt Operating the 4263B 2-11...
Page 22
All manuals and user guides at all-guides.com 4263B Selecting the Deviation Mode 1ABS 2-12 Operating the 4263B...
Page 23
All manuals and user guides at all-guides.com 4263B Selecting the Display Mode Data Cmprtr Digit Data Cmprtr Digit Operating the 4263B 2-13...
Page 24
All manuals and user guides at all-guides.com 4263B Using the Level Monitor Function Off Imon Vmon Both Imon Vmon Both 2-14 Operating the 4263B...
Page 25
All manuals and user guides at all-guides.com 4263B Selecting the Beeper Mode Beep Exit Setting the Printer|Printing the measurement data Talk Only Operating the 4263B 2-15...
All manuals and user guides at all-guides.com 4263B Figure 2-2. Printer Output Connecting the DUT Figure 2-3. Connecting the DUT 2-16 Operating the 4263B...
All manuals and user guides at all-guides.com 4263B Applying the DC Bias DC Bias ON/OFF indicator DC Bias ON/OFF indicator Making a Measurement Operation Manual Verication of Current Settings Operating the 4263B 2-17...
May Be Selected For Th is Primary Parameter D Q G Rp D Q Rs D Q G Rp Rdc D Q Rs Rdc M R2 This para meter is measured using the transformer measurement conguration (two-terminal measurement conguration). Operating the 4263B 2-19...
Page 30
All manuals and user guides at all-guides.com 4263B Note Accessories Available 16064B LED Display/Trigger Box Test Fixtures and Test Leads 2-20 Operating the 4263B...
Page 31
All manuals and user guides at all-guides.com 4263B Operating the 4263B 2-21...
Page 32
All manuals and user guides at all-guides.com 4263B Accessories List 16085B adapter required. Cables adapted to APC7 on each end required. Don't connect ground-lead to 4263B. Note 2-22 Operating the 4263B...
This range is not available for the 100 kHz test frequency setting. Other Topics Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operating the 4263B 2-23...
Page 34
All manuals and user guides at all-guides.com...
All manuals and user guides at all-guides.com Measurement Examples In This Chapter Measurement Examples...
Page 36
All manuals and user guides at all-guides.com 4263B Electrolytic Capacitor Measurement|For High Capacitance Requirements Measurement Setup For high capacitance measurement, equivalent series parameter Cs-D is commonly used. Even though LVL:1 Vrms is set, less than 0.5Vrms which is maximum appliable volatge for testing...
Page 37
All manuals and user guides at all-guides.com 4263B Measurement Examples...
Page 38
All manuals and user guides at all-guides.com 4263B OpenMeas Out Of Limit Measurement Examples...
Page 39
All manuals and user guides at all-guides.com 4263B ShortMeas Out Of Limit For More Information Measurement Examples...
Page 40
All manuals and user guides at all-guides.com 4263B Inductor Measurement|Versatile measurement parameters Requirements Test Fixture Measurement Setup Measurement Procedure Measurement Examples...
Page 41
All manuals and user guides at all-guides.com 4263B 100 kHz Measurement Examples...
Page 42
All manuals and user guides at all-guides.com 4263B 100 mV OpenMeas Out Of Limit Measurement Examples...
Page 43
All manuals and user guides at all-guides.com 4263B ShortMeas Out Of Limit Note Measurement Examples...
Page 44
All manuals and user guides at all-guides.com 4263B For More Information 3-10 Measurement Examples...
Page 45
All manuals and user guides at all-guides.com 4263B Transformer Measurement (Option 001 Only) Requirements Measurement Setup Measurement Procedure Measurement Examples 3-11...
Page 46
All manuals and user guides at all-guides.com 4263B 100 kHz 100 mV 3-12 Measurement Examples...
Page 47
All manuals and user guides at all-guides.com 4263B OpenMeas OUT OF LIMIT Note L2-N L2-1/N L2-M L2-R2 Measurement Examples 3-13...
Page 48
All manuals and user guides at all-guides.com 4263B OVLD OVLD For More Information L2-M L2-R2 3-14 Measurement Examples...