Download Print this page

Panasonic TC-21PM50A Manual page 9

Advertisement

2.6. PAL Colour
1. Receive the PAL B/G studio colour bar pattern and adjust local
frequency at the best tuned position.
2. Pic Menu: Dynamic Normal, Confirm Contrast - 100AC, Sub
Contrast - 21DAC.
3. Channel colour set --------- STD.
4. "CHK2" and press digit key "5" (AKB OFF) also confirm OSD
become blue colour.
5. Set ABL OFF (Note : ABL is set off in (CHK2).
6. Set (A) to 2.3 ± 0.2V by BRT (CHK2) at measurement point TPL 2
Fig. 4.
2.7. Adjustment
1. Connect oscilloscope probe to TPL 2 (G OUT) with 10k
resistor and adjust Contrast so that (B) as in Fig. 4 is 2.6 ± 0.1V.
2. Adjust "Sub Colour" so that waveform as in Fig. 4 (1) 2.5 ± 0.1V.
3. Connect oscilloscope probe to TPL 1 (R OUT) with 10k
resistor and confirm waveform as in Fig. 5 is (2) 2.7 ± 0.4V.
4. Set ABL ON (Note : Exit (CHK2 mode).
5. Press digit key "5" (AKB ON) and confirm the OSD become white
colour.
9
Fig. 3
series
series

Advertisement

loading