DIAT SECTION
DIAT SIGNAL RF LEVEL ADJUSTMENT
This adjustment is performed in order to adjust the transmission
distance of RF signal for DIAT communication.
Connection:
TX board
TP815
Procedure:
1. Connect the oscilloscope to TP815 and GND on the TX board.
2. Connect DIR-T1 to DIR-T1 jack (I/O board: J602).
3. Adjust RV801 on the TX board so that the center of waveform
becomes 1.0 Vp-p.
4. Confirm trigger is locked.
5. Adjust RV801 on the TX board so that the center of waveform
becomes 2.2 to 2.4 Vp-p.
RF Signal Reference Waveform
Adjustment Location:
– TX Board (SIDE A) –
TP815
RV801
SECTION 6

ELECTRICAL ADJUSTMENT

oscilloscope
VOLT/DIV : 500 mV
TIME/DIV : 500 ns
level : 2.2 to 2.4 Vp-p
HDMI SECTION
ADJUSTMENT OF VIDEO SYSTEM
[TEST DISC LIST]
Use the following test disc on this mode.
• HLX-504 (NTSC Test Disc 504): J-6090-088-A
Connection:
Set Back Panel
MONITOR OUT (VIDEO)
COMPONENT VIDEO OUT (Y)
1. Composite Level Adjustment (MIB01 Board)
<Purpose>
This adjustment is made to satisfy the standard, and if not adjusted
correctly, the brightness will be too large or small.
Mode
Video level adjustment in test mode
Signal
Color bar 100% (HLX-504 Track1)
Test point
MONITOR OUT (VIDEO) connector
(75 Ω terminated)
Instrument
Oscilloscope
Adjusting element
RV501
Specification
1.0 Vp-p
Procedure:
1. Terminate the MONITOR OUT (VIDEO) connector in 75 Ω.
2. Connect an oscilloscope across 75 Ω terminator.
3. Turn the power on.
4. Set the test disc (HLX-504) on the tray and press
to playback.
5. Confirm that oscilloscope waveform is clear and check
composite output level is correct or not.
6. If it is not correct, adjust the RV501 to attain 1.0 Vp-p.
2. Component Output Level Adjustment (MIB01 Board)
<Purpose>
This adjusts component output level. If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bar 100% (HLX-504 Track1)
Test point
COMPONENT VIDEO OUT (Y)
connector (75 Ω terminated)
Instrument
Oscilloscope
Adjusting element
RV502
Specification
1.0 Vp-p
HCD-FX100W
oscilloscope
75 Ω
H
button
1.0 Vp-p
27