Technical data

Hob dimensions
Width
Depth
Built in height
Gas original:
Gas replacement:
Gas connection: R 1/2"
Burner type Injector mark
Multi Crown
Semi-rapid
(medium)
Auxiliary
(small)
595 mm
510 mm
40 mm
TOTAL POWER
G25.3 (2EK) 25 mbar = 8,85 kW
G25 (2L) 25 mbar = 8,85 kW
G30/G31 (3B/P) 30/30 mbar = 621 g/h
G20 (2E) 20 mbar = 8,7 kW
Nominal Pow‐
er kW
G25.3 25 mbar / G25 25 mbar
144°
3.85
98x
2.0
071
1.0
G30/G31 30/30 mbar
Other technical data
Class Appliance: 3
Appliance Category: II2EK3B/P;
II2L3B/P
Appliance gas supply: Natural gas
G25.3 (2EK) 25 mbar; G25 (2L) 25
mbar
This model is designed for use
with natural gas G25.3 25 mbar /
G25 25 mbar but can be
converted for use with natural
gas G20 20 mbar, butane or
propane gas G30/G31 30/30 mbar
providing the correct injectors.
The injectors not supplied with
the appliance have to be ordered
from After Sales Service (refer to
the Service chapter).
Nominal Flow
Reduced Pow‐
g/h
-
-
-
by-pass
er kW
1.4
57
0.6
35
0.33
28
34