Replacing The Plug - Siemens SCALANCE W778-1 Operating Instructions Manual

Simatic net industrial wireless lan scalance
Hide thumbs Also See for SCALANCE W778-1:
Table of Contents

Advertisement

Connection

6.5 Replacing the PLUG

NOTICE
UL approval only for use in buildings
Within the area of authority of the NEC and CEC, the SCALANCE W778/W738 devices
and the antennas connected to them may only be used in a closed building. For this
reason, do not lead antennas into the outdoor area if you need to meet UL or CSA
requirements.
Note
Cabinet installation
When installing the SCALANCE W device in a cabinet, you need to use detached
antennas. A suitable flexible connecting cable for the connection between SCALANCE W
and a detached antenna is available from SIMATIC NET. You will find detailed
information in the section Accessories (Page 21).
6.5
Replacing the PLUG
Position
The PLUG slot is at the top of the device under a cover, see Reset button (Page 31).
NOTICE
Operating risk - Danger of data loss
Only pull and plug the PLUG when the device is de-energized.
Removing the PLUG
Follow the steps below to remove a PLUG from the device:
1. Turn off the power to the device.
2. Release the screw of the slot cover and swing the slot cover to the side.
58
SCALANCE W778-1 / W738-1
Operating Instructions, 03/2022, C79000-G8976-C450-07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents