  • Page 1 560i and testo Smart Valve 0564 1560 0560 5600 Instruction manual...
  • Page 2: Table Of Contents

    Switching the instrument on and off ............9 Establishing a Bluetooth connection ............. 9 ® Establishing a Bluetooth connection to the testo Smart App ....10 ® 7.3.1 Establishing a Bluetooth ® connection to the testo 550s / testo 557s 7.3.2...
  • Page 3 Removing oil residues ................. 34 Ensuring measuring accuracy ............. 34 Changing batteries/rechargeable batteries .......... 35 Technical data ..................36 Technical data for testo 560i ..............36 10.1 Technical data for testo Smart Valve ........... 37 10.2 Tips and assistance ................37 Accessories ..................
  • Page 4: About This Document

    Control keys of the instrument or buttons of the program interface. 2 Safety and disposal Please observe the Testo information document (enclosed with the product). 3 Product-specific approvals For the relevant country approvals, please refer to the printed quick reference...
  • Page 5: Product-Specific Information

    Use with A2L refrigerants • Testo measuring instruments (as of July 2020) can be used in compliance with the prescribed laws, standards, directives and safety regulations for refrigeration systems and refrigerants as well as regulations of the manufacturers of refrigerants of safety group A2L as per ISO 817.
  • Page 6: Intended Use

    The testo 560i and testo Smart Valve can be used either in conjunction with the testo Smart App or in conjunction with one of the testo 550s and testo 557s manifolds. The testo Smart Valve is compatible with most non-corrosive refrigerants, water and glycol.
  • Page 7: Product Description

    6 Product description 6 Product description Overview of testo 560i Battery compartment (on rear) It is not possible to charge 1 On/off switch rechargeable batteries in the instrument.
  • Page 8: Overview Of Testo Smart Valve

    6 Product description Overview of testo Smart Valve On/off switch - 1x click: Switch on 1 Folding suspension device (rear) - Hold down: Switch off - 3x clicks: Open valve for 1 s Battery compartment (on rear) Status LED It is not possible to charge...
  • Page 9: First Steps

    In Bluetooth ® connection mode, connection can be established to the testo Smart App or to a testo 550s or testo 557s manifold. Do not change or remove batteries during operation, otherwise the charging process will be interrupted. When not in use for a long period: Take out the (rechargeable) batteries.
  • Page 10: Switching The Instrument On And Off

    Smart App or to a testo 550s or testo 557s manifold. Press and hold the ON key.  The instrument is switched off. Establishing a Bluetooth connection ® The testo 560i scale or the testo Smart Valve are switched on. ...
  • Page 11: Establishing A Bluetooth ® Connection To The Testo Smart App

    To establish a connection via Bluetooth ® , you need a tablet or smartphone with the Testo Smart App already installed on it. You can obtain the app for iOS devices from the App Store, for Android devices from the Play Store or by scanning the QR code in the manifold.
  • Page 12: Switching On

    7 First steps Bluetooth menu is displayed.  Switching on 7.3.2.1  Bluetooth menu is selected. [Menu/Enter] In the On/Off switch icon,  displayed. Enable Bluetooth®: Use [▼] activate the [Completed] button and [Menu/Enter] to confirm. When the Bluetooth ® icon appears on the display, Bluetooth ®...
  • Page 13: Using The Product

    ® switched off. 8 Using the product The testo 560i scale and the testo Smart Valve can either be used in conjunction with the testo Smart App or in conjunction with one of the testo 550s and testo 557s manifolds.
  • Page 14: Control Via App

    8 Using the product Control via app Scale and valve are switched on.  The app is installed on the smartphone and connected to the valve  and scale via Bluetooth®. Settings and controls are implemented via the app.  Open main menu Display of the measurement period Display of the maximum system charging...
  • Page 15 8 Using the product Further symbols on the user interface (without numbering) One level back Exit view Share measurement data/report Search Favourite Deleting Further information Display report Multiple selection Main menu can be accessed via the icon at top left. To exit the main menu, select a menu or right-click on the guided menus.
  • Page 16: Creating And Editing A Customer

    8 Using the product Creating and editing a customer 8.1.1 Customer In the menu, all customer and measuring site information can be created, edited and deleted. Fields marked with * are mandatory. Without any information in this field, no customers or measuring sites can be stored. Click on ...
  • Page 17: Creating And Editing Measuring Sites

    8 Using the product Creating and editing measuring sites 8.1.2 Click on  Main menu opens. Click on Customer.  Customer menu opens. Click on + New Customer. Measuring Points. Click on right tab Click on + New Measuring Point. ...
  • Page 18: Searching For And Deleting Measurement Results

    8 Using the product For the duct, outlet or duct with k-factor measuring points, further parameter settings can be implemented. Click on Save.  The new measuring site has been saved. Searching for and deleting measurement 8.1.3 results Memory In the menu, you can call up all the stored measurements, analyze them in detail and also create and save csv data and PDF reports.
  • Page 19: Sensors

    Information 8.1.4.1 Information is stored for each probe. The app is connected to testo 550s / testo 557s.  Click on  Main menu opens.
  • Page 20: Settings

    8 Using the product  Information is displayed about the model, order number, serial number and firmware version. Settings 8.1.4.2 Settings can also be made for each probe. The probe is connected to the App.  Click on  Main menu opens. Click on Sensors.
  • Page 21: Measurement Settings

    8 Using the product Measurement settings 8.1.6 Click on Settings.  The Settings menu opens. Click on Measurement settings.  A window with different basic settings for measurement opens. Click on the required settings and change if necessary.  The required measurement settings are set. Measurement settings.
  • Page 22: Help And Information

    Help and Information 8.1.9 Under Help and Information, you will find information about the testo 550s / testo 557s, and the tutorial can be called up and implemented. This also where legal information can be found. Instrument information 8.1.9.1...
  • Page 23: Control Via Manifold

    Bluetooth ® The firmware of the manifold is up to date.  The firmware is updated by downloading the latest testo Smart App from the App Store or Play Store. Settings and controls are implemented via the manifold.  Manifold main menu...
  • Page 24: Connecting The Instruments

    Protect the testo Smart Valve from vibrations. Otherwise, safe opening and closing cannot be guaranteed. If the testo Smart Valve is subjected to a hard impact or a fall, it must be switched on and off again. Otherwise, the valve position may be lost.
  • Page 25: Manual Charging Via Weight

    Manual charging via weight This function enables a refrigerant circuit to be charged manually via weight using the testo 560i in combination with the app or testo 550s / testo 557s manifold. By manually opening and closing the valve, the system is charged with refrigerant until the target value (weight/superheating/subcooling) is reached.
  • Page 26 8 Using the product If necessary, zero sensor on manifold/app [P = 0]. Open valve(s) manually and add refrigerant to the system until the required value is reached.  Added refrigerant is displayed in g/kg increments on the manifold/app.
  • Page 27: Automatic Charging By Target Weight

    Automatic charging by target weight This function enables the system to be charged automatically with an input target weight using the testo 560i scale and the testo Smart Valve in combination with the app or the testo 550s / testo 557s manifold.
  • Page 28 8 Using the product In the app, set the required weight to be supplied to the system and use the [▼] button to start the process. The valve opens and  attempts to fill with the set charge quantity. No pulsating charging takes place.
  • Page 29: Automatic Charging By Target Superheat

    This function enables a refrigerant circuit to be charged via the target superheat value using the testo 560i scale and the testo Smart Valve in combination with the app or testo 550s / testo 557s manifold. For this, the current superheating value is determined. Based on this information, a target superheat value can be entered.
  • Page 30 8 Using the product Set the required target superheat value to be reached on the manifold/app and use the [▼] button to start the process. The valve opens and  attempts to reach the set superheat by charging refrigerant.  Added refrigerant is displayed in g/kg increments on the manifold/app.
  • Page 31: Automatic Charging By Target Subcooling

    This function enables a refrigerant circuit to be charged via the target subcooling value using the testo 560i scale and the testo Smart Valve in combination with the app or testo 550s / testo 557s manifold. For this, the current subcooling value is determined. Based on this information, a target subcooling value can be entered.
  • Page 32 8 Using the product Set the required target subcooling value to be reached on the manifold/app and use the [▼] button to start the process. The valve opens and  attempts to reach the set subcooling by charging refrigerant.  Added refrigerant is displayed in g/kg increments on the manifold/app.
  • Page 33: Automatic Charging Via Target Superheat

    This function enables a refrigerant circuit to be charged via the target superheat using the testo 560i scale and the testo Smart Valve in combination with the app or the testo 550s / testo 557s manifold. For this, two testo 605i Smart Probes are connected to the manifold or the testo Smart App.
  • Page 34 8 Using the product Set the required target superheat value to be reached on the manifold/app and use the [▼] button to start the process. Refrigerant is  automatically supplied to the system until the set value is reached.  Added refrigerant is displayed in g/kg increments on the manifold/app.
  • Page 35: Maintenance

    9 Maintenance 9 Maintenance Calibration The testo 560i scale and the testo Smart Valve are supplied with a factory calibration certificate as standard. Recalibration once every 12 months is recommended in many applications. This can be carried out by Testo Industrial Services (TIS) or other certified service providers.
  • Page 36: Changing Batteries/Rechargeable Batteries

    In Bluetooth connection mode, connection can be established to the ® testo Smart App or to a testo 550s or testo 557s manifold. Do not change or remove batteries during operation, otherwise the charging process will be interrupted. When not in use for a long period: Take out the (rechargeable) batteries.
  • Page 37: Technical Data

    In Bluetooth connection mode, connection can be established to the ® testo Smart App or to a testo 550s or testo 557s manifold. Do not change or remove batteries during operation, otherwise the charging process will be interrupted. When not in use for a long period: Take out the (rechargeable) batteries.
  • Page 38: Technical Data For Testo Smart Valve

    11 Tips and assistance 11.1 Accessories Description Order no. Magnetic strap for valve 0564 1001 For a complete list of all accessories and spare parts, please refer to the product catalogues and brochures or visit our website www.testo.com...
  • Page 39: Support

    You can find up-to-date information on products, downloads and links to contact addresses for support queries on the Testo website at: www.testo.com. If you have any questions please contact your local dealer or the Testo Customer Service. You can find contact details on the back of this document or...
  • Page 40 Testo SE & Co. KGaA Celciusstrasse 2 79822 Titisee-Neustadt Germany Phone: +49 (0)7653 681-0 E-mail: info@testo.de Internet: www.testo.com 0970 5610 en 01 – 04.2022...

This manual is also suitable for:

Smart valve0564 15600560 5600056415600560 ... Show all