10. USING A LINEAR SERVO MOTOR

10.2.2 Power supply capacity and generated loss

Table 10.1 indicates servo amplifiers' power supply capacities and losses generated under rated load. For
thermal design of an enclosed type cabinet, use the values in the table in consideration for the worst
operating conditions. The actual amount of generated heat will be intermediate between values at rated
torque and servo-off according to the duty used during operation. When the linear servo motor is run at less
than the rated speed, the power supply capacity will be smaller than the value in the table, but the servo
amplifier's generated heat will not change.
Mounting a heat sink outside of the cabinet enables to reduce heat in the cabinet and design a compact
enclosed type cabinet.
Table 10.1 Power supply capacity and generated loss per linear servo motor at rated output
Linear servo motor
LM-FP5H-60M-1SS0
Note 1.
Note that the power supply capacity will vary according to the power supply impedance. This value is applicable when the
power factor improving AC reactor or power factor improving DC reactor are not used.
2.
Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, refer to section 9.2.
Power supply
Servo amplifier
capacity [kVA]
(Note 1)
MR-J4-22KB4(-RJ)
MR-J4-22KA4(-RJ)
Servo amplifier-generated heat [W]
(Note 2)
At rated output
22
640
10 - 5
Area required for
heat dissipation
[m2]
With servo-off
45
12.8