Lead Inspection Checker
10.2
Set the Method for Lead Inspection
6.
Normally, use with the Condition item set to its default value.
Change the Condition setting if detection is not working well,
or if you want to reduce the detection time.
[4] LEAD INSPECTION Detected:NG Cnt. : 0
No. 1
2.
26.
261.
262.
263.
264.
Scan Pitch
This sets the number of pixels for the scanning interval with respect to the scan direction
in the inspection area. The initial (default) value is 1.
Setting a wide pitch makes inspection faster, but there is a greater interval between the
sections examined. If the pitch is set wider than the scanning area, only a single line
is scanned.
Scanning Pitch = 1
Scanning direction
Filter
Width
This item allows you to change the conditions for the lead edges (contours). Refer to
the following page for details.
10 − 6
Width: OK Pitch:OK
Checker Setting
Condition
Scan Pitch
Filter
Width
Average Area
Scanning Pitch = 2
1
3
5
5
Scanning direction