Technical specifications for rechargeable
battery
– Nanophosphate
high-power lithium-ion
®
rechargeable battery, cadmium-free LiFePO
– Can be recharged at any time without shortening
battery lifespan.
– Automatic recharging by solar panel.
– Can be recharged using charging adapter at
micro USB socket (5 V).
– Can be replaced by the manufacturer or
qualified electricians.
– Rechargeable battery capacity: 2500 mAh
– Max. lighting duration:
60 days at 20 switching operations a night.
– Micro USB charging socket: 5 V, 1 A max.,
can be used in all three programmes.
Recharging time depends on the site of installa-
tion (direct sunlight). Expect charging to take many
times longer in winter or on rainy days.

4. Installation

• Check all components for damage.
• Do not use the product if the solar panel or
LED panel is damaged.
Operating reliability will be limited if the product is
used in adverse conditions (e.g. installed in shade
or behind glass, solar panel not facing the right
direction)
• Choose an appropriate site with plenty of sun-
light for installing the solar panel (facing south).
• Avoid shade from porches, overhanging roofs
or trees.
• Pay attention to detection reach (Ill. 4.1).
• Remove wall mount (Ill. 4.2).
• Drill holes and fit rawl plugs (Ill. 4.3).
• Screw-fasten wall mount to the wall (Ill. 4.3).
• Make settings (Ill. 4.4).
➔ "6. Operation"
• Screw SensorLight to wall mount (Ill. 4.5).
• Aim LED panel with motion detector in the right
direction (Ill. 3.4).
• Aim solar panel to get the strongest sunlight for
the longest time possible (Ill. 3.4).
• Check compass (for south-facing position)
(Ill. 3.4).

5. Operation

Before using for the first time
• Activate light by setting the programme selector
.
4
switch to P2.
The light stays in test mode for one minute
before it starts to work in programme P2.
Test mode
During the test sequence the light works in
daytime mode.
On detecting movement, the light switches ON
for 1 minute with a stay-ON time of 10 sec. irre-
spectively of light-level setting. The programme
is automatically activated after this time elapses.
The red LED stays ON all the time in test mode.
Setting the chosen operating mode by
programme selector switch
– P0: OFF (factory setting).
Loads (LED panel and sensor) are deactivated.
– P1: Sensor mode.
Light only switches ON after receiving a signal
from the motion detector.
– P2: Sensor mode with basic light level.
Light switches ON after receiving a signal from
the motion detector.
Light permanently ON in the morning and
evening hours at reduced basic light level.
Stay-ON time and brightness
– Stay-ON time is determined when the light is
used for the first time.
– During the first night, basic lighting is switched
OFF in the morning in programme 2.
– Stay-ON time and brightness can be automati-
cally matched to ambient conditions, e.g. stay-
ON time is longer in summer than it is in winter.
– Basic lighting level provides night-time illumina-
tion at approx. 3% light output. Light is switched
to maximum output when movement is identified
in the detection zone. The light then returns to
basic lighting level (approx. 3%).
The period basic lighting is provided for is
matched to ambient conditions. Using basic
lighting reduces light availability. If it is not need-
ed, it is recommended to switch it OFF (P1) to
ensure lighting availability in less sunny periods.
Charging the battery manually
The red LED in the motion detector flashes if
battery capacity is too low (e.g. in poor weather).
The battery can be recharged with a standard
micro USB charging adapter (not included). Battery
recharging can take up to 6 hours.