L
ack
emovaL and
ower
To remove the back:
1. Remove the left and right side panels (see the previous
page).
2. If the stove is connected to the vent pipe, loosen the four
5/32" allen head screws (see A in Figure 51) securing the
lower cover plate beneath the flue outlet, lift the plate
slightly, and pull the plate off.
3. Loosen the two screws B and C shown in Figure 52 and
the corresponding two screws on the other side of the
stove. The back can now be pulled to the rear and off of
the stove.
To reinstall the back, follow the steps just listed - but in the
reverse order.
c
i
omponent
nFormation
The following is a list of components and their functions.
Igniter
The Winslow™ PS40 stove comes equipped with an automatic
igniter for lighting the fuel when the stove is in the lighting
mode. The igniter superheats air that is pulled through the
burn pot by the combustion blower to light the fuel. The
igniter remains energized for the first seven minutes of the
lighting sequence.
Vacuum Switch
The Winslow PS40 stove has a vacuum switch located
behind the left door, fastened to the pedestal base (see D
in Figure 52). If a low pressure is created in the firebox by
a leak, opening the front door, a blocked flue, or unsealed
ash drawer, the vacuum switch will sense it and cause the
stove to go into a shutdown mode.
Auger and Auger Motor
The 1.25 RPM auger motor turns the auger, lifting pellets
up the auger tube. The pellets are then dropped down a
tube and into the firepot. The auger is controlled by the
control board.
over Temperature Snap Switch (Manual Reset)
(Opens at 225F) This switch is installed on the convection
blower (see F in Figure 53) and shuts the stove down if it
senses excessive temperatures. This snap switch has a reset
button on it and will not allow the stove to start up until the
reset button has been pushed.
Proof of fire Snap Switch
(Closes at 140F) This switch is installed on the combustion
blower (see E in Figure 52) and shuts the stove down if it
senses no fire in the burn pot.
Convection blower Snap Switch
(Closes at 120F) This switch is installed on the right rear
of the firebox and turns the convection blower on when the
stove gets up to temperature.