OPERATION INDICATOR
OPERATION INDICATOR
Once the generator is working in the normal mode, output voltage light is green. In case of overload, indicator lights red.
After 2 minutes working in overload mode, protection device switches on and turns off the power generation to protect
the connected electrical equipment and generator. In the event of a short circuit, protection device immediately shuts
off electricity. In both cases, indicator is blinking red, but the engine does not stop.
Restart the engine to make the generator produce electricity again.
IMPORTANT!
Before you start working with the generator, please fill it with a mixture of gasoline and oil. Provide adequate ventilation
for the generator not be overheated during the operation. Do not allow the leaking of gasoline, and beware of fire and
sparks.
IMPORTANT!
TO ADD FUEL:
TO ADD FUEL:
1. Remove the fuel cap
2. Pour the mixture into the fuel tank with a funnel
3. Tightly screw the fuel cap
Recommended fuel:
Recommended fuel: mixture of gasoline and oil.
Fuel tank volume: see specifications table.
Fuel tank volume:
IMPORTANT!
IMPORTANT!
Before starting the engine,
Before starting the engine, make sure that the rated power of power consumers matches with the power of generator.
Do not exceed the nominal power of the generator. Do not connect any devices before you start the engine!
IMPORTANT!
ATTENTION – DANGER!
COMMISSIONING
COMMISSIONING
1. Check fuel level.
2. Check the air filter for correct installation
If case the excessive amount of gasoline that has arisen thought
non-compliance startup creates difficulties when you first start the
engine, unscrew the spark plug, completely open the air flaps and
repeatedly pull the starter handle. Then tighten the spark plug in
place to run the generator.
CHECK BEFORE GETTING STARTED
Use a mixture of oil and gasoline at a ratio of only 50:1 (2%)! Manu-
facturers produce oil for 2-stroke engines of different concentrations
25:1 or 50:1. Mixture of oil ratio of only 50:1 is recommended for the
generator (this is indicated on the oil package).
Wipe up spilled fuel immediately with a clean, dry, soft cloth, as the
fuel may harm painted surfaces or plastic parts.
Without adding oil to the gasoline engine overheats and piston
may jam. You can use any oil from for known manufacturers for two-
engines with air-cooling.
Do not connect any devices before you start the engine!
Do not change the controller settings in terms of the amount of
fuel or speed governor (this adjustment was made at the factory).
Otherwise, this may result in changes in the engine operation or its
failure.
In the power supply mode, the generator should operate no longer
than 1 minute in the range from nominal to maximum power.

GETTING STARTED