REMOVING THE OVEN RELAY PCB, POWER PCB
!
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
!
CAUTION
• Be careful when you work on the
electric range handling the sheet
metal part.
- Sharp edge may be present and you can cut
yourself.
1. Turn off the electrical supply going to the range.
2. Pull the range away from the wall so that you can
access the rear panel.
3. Remove back cover (See step 3 on page 3-2)
COMPONENT ACCESS
!
!
Power PCB
4. To remove the PCB, Disconnect the 8 ea housing
and remove the 2ea screw.
3-3
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes