Step 5-3
A • Ground/Green
Step 5-4
B • Ceiling Black
• Receiver Black: "LIVE IN"
C • Ceiling White
• Receiver White: "NEUTRAL IN"
Step 5-5
D • Fan Black with a white stripe
• Receiver Red: "LIGHT OUT"
E • Fan Black
• Receiver Black: "FAN OUT"
F • Receiver White: "COMMON OUT"
• Fan White
Large Wire
Connector
All wiring must be in
accordance with national
and local electrical codes
and ANSI/NFPA 70. If you
are unfamiliar with wiring,
use a qualified electrician.
Small Wire
Connector
5 • Wiring the Fan
5-1. Before attempting installation, make sure the power is still off.
5-2. To connect the wires, hold the bare metal leads together and place
Receiver
a wire connector over them, then twist clockwise until tight. For
all these connections use the wire connectors provided.
F
CAUTION: Be sure no bare wire or wire strands are visible after
making connections.
5-3. Using a large wire connector, connect the ground wire from the
ceiling (grounding) to the green wire (grounding) from the ceiling
plate and the green ground wire from the downrod.
E
5-4. Using the large wire connectors, connect the white wire
(grounded) and the black wire (ungrounded) from the ceiling as
follows:
• The white (common) power wire (grounded) from the ceiling to
the white wire (grounded) from the receiver (marked on red tag
"NEUTRAL IN")
• The black power wire (ungrounded) from the ceiling to the
black wire (ungrounded) from the receiver (marked on red tag
"LIVE IN")
5-5. Using the small wire connectors, connect the wires from the fan as
follows:
• The black wire with a white stripe (ungrounded) from the fan
to the red wire (ungrounded) from the receiver (marked on
white tag "LIGHT OUT")
Steps 5-3 – 5-5
• The black wire (ungrounded) from the fan to the black wire
(ungrounded) from the receiver (marked on white tag
"FAN OUT")
• The white wire (grounded) from the fan to the white
wire (grounded) from the receiver (marked on white tag
"COMMON OUT")
5-6. Turn the splices upward and push them carefully back through the
ceiling plate into the outlet box.
5-7. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the
outlet box.