Carrier 30GT-911---062 Installation Instructions Manual

Air-cooled chillers with comfortlink controls; water-cooled chillers with comfortlink controls; rooftop units with comfortlink controls; navigator accessory display module

Advertisement

Read these instructions completely before attempting to in-
stall the Navigator Accessory Display Module. The Navigator
module is used on the following units:
UNIT
30HK
30HL
30HW
30RB
48AJ,AK,AW,AY
50AJ,AK,AW,AY
48PG
50PG
48ZG,ZN
48ZT,ZW,Z6,Z8
50ZG,ZN,Z2,Z3
50ZT,ZW,ZX,ZZ,Z6,Z7,Z8,Z9

CONTENTS

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10, 11
CLEANING, SERVICE, AND MAINTENANCE . . . . . 12
SAFETY CONSIDERATIONS
Installation of this accessory can be hazardous due to sys-
tem pressures, electrical components, and equipment location
(such as a roof or elevated structure).
Only trained, qualified installers and service technicians
should install, start up, and service this equipment.
When installing this accessory, observe precautions in the
literature, labels attached to the equipment, and any other
safety precautions that apply.
• Follow all safety codes.
• Wear safety glasses and work gloves.
• Use care in handling and installing this accessory.
To avoid the possibility of electrical shock, open and tag
all disconnects before installing this equipment. Be
aware that there may be more than one disconnect.
GENERAL
Check Package Contents —
package for missing parts or shipping damage. If damage is
found, or any part is missing, file a claim with the shipper
immediately. The package contains these instructions, carrying
bag, and the Navigator display module.
The Navigator module is a portable display that conforms to
NEMA (National Electrical Manufacturers Association) 4
specifications for outdoor use in temperatures ranging from
–22 F (–30 C) to 158 F (70 C). The Navigator module can be
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 533-00078
Book 1
1
2
4
4
Tab
1a 1b 5c 6a 6b
Air-Cooled Chillers with ComfortLink™ Controls
Water-Cooled Chillers with ComfortLink™ Controls
Rooftop Units with ComfortLink™ Controls

Installation Instructions

Part Number 30GT-911---062
SIZE
040-060
050-060
018-040
060-390
020-060
020-060
03-28
03-28
030-105
075-105
030-105
075-105
Check the accessory
Printed in U.S.A.
Navigator™ Accessory Display Module
used to configure and perform service diagnostics on machines
equipped with Carrier ComfortLink controls.
The Navigator module keypad (see Fig. 1) contains eleven
menu LEDs and one Alarm Status LED, all of which are
red. The Navigator module is capable of displaying four
24-character lines of information on a back-lit liquid crystal
display. The Navigator module has four functional keys: the up
arrow (
), down arrow (
keys.
NOTE: The Navigator module should be removed after use.
There is not sufficient space to store the module in the unit
control panel. The module will NOT fit between the inner
panel and outer cover.
Fig. 1 — Navigator in Display Mode
INSTALLATION
1. The Navigator display module is intended to be a mobile
device, so there are no holes in the device for permanent
mounting. The module has a magnetic mount that is
strong enough to hold the device in place on any clean,
dry metal surface.
2. The Navigator module is powered through the
ComfortLink Main Base Board (MBB). The Navigator
module has a modular telephone style (RJ14) connector
and should be connected to a specific terminal block in
the control box as found in Table 1. This device is intend-
ed for use on the LEN (Local Equipment Network) com-
munications bus only. Do NOT connect the Navigator
module to the CCN (Carrier Comfort Network®) con-
nector, as it may damage the device.
3. See Fig. 2-8 for Navigator LEN connection locations in
the units.
4. See Fig. 9 for Communication board details.
Form 30/48/50-6SI
Pg 1
),
, and
ENTER
ESCAPE
a30-3924
10-06
Replaces: 30G,H,R-1SI

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 30GT-911---062

  • Page 1: Installation Instructions

    LEN (Local Equipment Network) com- munications bus only. Do NOT connect the Navigator module to the CCN (Carrier Comfort Network®) con- nector, as it may damage the device. 3. See Fig. 2-8 for Navigator LEN connection locations in the units.
  • Page 2 CB-FN — Circuit Breaker Fan Circuit CB-HT — Circuit Breaker Cooler Heater CB-P — Circuit Breaker Pump — Control Circuit Board — Carrier Comfort Network CLHR — Cooler Heater Relay — Control Relay — Current Sensor — Current Sensor Board —...
  • Page 3 FIELD POWER SUPPLY Fig. 2 — 30HK,HL040-060 Units Navigator™ LEN Connection MARQUEE DISPLAY SETPOINT POTENTIOMETER (DOMESTIC-STANDARD) (EXPORT ONLY) (EXPORT-OPTIONAL) SEE OTHER LABELS CONNECTIONS NAVIGATOR CONNECTION ENABLE ON/OFF CONTACT SWITCH EMERGENCY ON/OFF SWITCH a30-4460...
  • Page 4 NAVIGATOR LEN MARQUEE DISPLAY LOCATION CONNECTION a30-4461 Fig. 3 — 30HW018-040 Units Navigator™ LEN Connection...
  • Page 5 Fig. 4 — 30RB060-120 Units Navigator™ LEN Connection NAVIGATOR LEN CONNECTION NON-FUSED DISCONNECT OPTION a30-4462...
  • Page 6 a30-4463...
  • Page 7 a48-8278 NAVIGATOR LEN CONNECTION Fig. 6 — Typical 48/50PG Series Navigator™ LEN Connection...
  • Page 8 CONTROLS OPTION BOARD NAVIGATOR LEN CONNECTION a48-8279 Fig. 7 — Typical 48/50A Series Navigator™ LEN Connection...
  • Page 9 a48-8280...
  • Page 10 LEN port. On power up, the Navigator module displays: ComfortLink Navigator Carrier The Navigator module will upload the appropriate display tables from the Main Base Board (MBB) that it is connected to. A ‘Communication failure’ message will be displayed if any errors are encountered.
  • Page 11 If an area is entered that is Password Protection — password protected or an item is selected for change that is password protected, the Navigator™ module will display: Enter Password The first digit of the password will be flashing. Hold either of the arrow keys down to change the value of the first digit (if necessary) and press to accept.
  • Page 12 5. Insert the rubber grommet (included with new cable as- sembly) into the cable entrance hole. Copyright 2006 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents