Error Messages - Roland TD-12 Manual

Hide thumbs Also See for TD-12:
Table of Contents

Advertisement

Apr.2005

ERROR MESSAGES

Backup Battery Low!
The internal backup battery of the TD-12 (a battery that maintains data in the
user memory) has run down.
Replace the battery.
Backup NG!
Data in the TD-12's memory may be corrupted. The TD-12's internal backup
battery (the battery used for saving User memory data) is fully drained;
internal data has been lost.
Replace the battery. Follow the messages appearing on the screen to carry out
Factory Reset; you will then be able to use the unit temporarily.
MIDI Communication Error!
It is possible that the power has been turned off for the MIDI device connected
to the TD-20's MIDI IN connector.
Check the power of the connected MIDI device.
System Error!
A problem has occurred with the internal system.
Check whether there is any fault in hardware.
Measure Maximum!
The maximum number of measures that can be recorded to one pattern has
been exceeded; no further recording or editing that adds measures can be
carried out.
Delete unneeded measures from the pattern being recorded or edited.
Step Maximum!
The maximum number of steps that can be recorded to one chain has been
exceeded; no further editing that adds steps can be carried out.
Delete unneeded steps from the chain being edited.
Data Overload!
Pattern contained an excessive amount of data, and as a result could not be
output successfully from MIDI OUT.
Try eliminating a part that has too much data.
Not Enough Memory!
Pattern recording or editing could not be carried out because there was not
enough internal memory.
Try deleting patterns that are no longer needed.
BULK DUMP Checksum Error!
The checksum value of a system exclusive message was incorrect.
Correct the checksum value.
BULK DUMP Receive Address Error!
The receive address of a system exclusive message was incorrect.
Correct the receive address.
BULK DUMP Receive Data Error!
A MIDI message was received incorrectly.
If the same error message is displayed repeatedly, there is a problem with the
MIDI messages that are being transmitted to the TD-12.
BULK DUMP Receive Time Out!
The interval in receiving system exclusive messages were too long.
Make the interval of the data shorter.
58
Messages
BULK DUMP Receiving... Please Wait.
Bulk data is now being received.
BULK DUMP Aborted!
Bulk data transmission was halted.
Preset Pattern!
You cannot record on the preset pattern.
Copy the pattern onto a user pattern.
Empty Pattern!
This pattern contains no performance data; it cannot be edited.
Select the other pattern that contains performance data.
No Empty Pattern!
There are no empty patterns for recording.
Delete unneeded pattern.
MIDI Offline!
A MIDI cable was disconnected. (Or communication with the external MIDI
device stopped for some reason.)
Make sure that MIDI cables have not been pulled out or broken.
MIDI Buffer Full!
A large amount of MIDI messages were received in a short time, and could not
be processed completely.
Confirm that the external MIDI device is properly connected. If the problem
persists, reduce the amount of MIDI messages sent to the TD-12.
Power On Too Long. Please Turn Off!
The power remains ON for a long time.
Turn the TD-12's power off, then turn on again.
Auto Shutdown Completed. Please Turn Off!
The power remains ON for a long time.
Turn the TD-12's power off, then turn on again.

Advertisement