The FT-23R has been aligned by highly-skilled
technicians at the factory, and is designed so that no
further alignment should ever be required. However, in
the unlikely event of a component failure, realignment
may be necessary. All component replacement and ser­
be
vice should
performed only by· an authorized Yaesu
representative , or the warranty policy may be voided.
Required Test Equipment
RF Signal Generator with calibrated output level at
1 50 MHz
Spectrum Analyzer
RF Sampling Coupler
Oscilloscope
Make sure the transceiver is off. Remove the hard or
soft case, if used, and remove the battery pack.
Remove the four screws affixing the battery spring
plate on the bottom of the transceiver, and carefully
remove the plate.
Pull off the knobs, and remove the f o ur screws affix­
ing the top panel. Remove the panel and rubber
gasket under it.
Remove the two screws affixing the front and re ar
halves of the c ase, and gently separate the halves,
using care not to stress the interconnecting wires.
)
B oard Locations
A L I G N M E N T
Case Disassem bly
I F U N I T
SW
A N T
U N I T
M OT H E R BOA R D
V C O U N IT
P L L U N I T
AF Millivoltmeter
Deviation Meter
SINAD Meter
Inline Wattmeter with 5% accuracy at 150 MHz
Regulated DC Power Supply adjustable from 10 to
1 5V, 2A
50-Q Non-reactive Dummy Load: l OW at 1 50 MHz
Frequency Counter: ±0.2ppm accuracy at 1 50 MHz
AF Signal Generator
DC Voltmeter: high impedance
External Loudspeaker or 8-Q load resistor.
2 - 1 3
C N T L U N IT
R E G U N IT
M I C A M P U N IT
D U M M Y U NIT

Advertisement