Download Print this page

Kohler K-3357 Installation Manual page 7

One-piece top-trip toilets
Hide thumbs Also See for K-3357:

Advertisement

Available languages

Available languages

Fill
Compression
Valve Nut
Washer
Supply
Shank
Seal
Compression
Washer
Nut
Ferrule
Coupling
Nut
Supply
Shut-Off
Valve
Supply Shut-Off Valve
Connection
4. Connect the Supply and Make Adjustments
Connect the supply shut-off valve to the toilet supply shank.
Open the supply shut-off valve slowly to check for leaks. If the
connections have been properly assembled, a slight tightening of
the nuts should stop leakage.
Install the toilet seat according to the packed instructions.
Adjustments
Adjust the tank to the marked waterline.
Rotate the threaded rod clockwise to raise the water level or
counterclockwise to lower the water level as needed.
Test flush the toilet several times, while checking all connections
for leaks, to ensure proper operation.
If the flapper ball does not seat properly when the lift rod is
lowered, provide more flapper chain by:
• Relocating the flapper chain S-hook to the bottom hole in the lift
rod.
• Repositioning the flapper chain S-hook on the flapper chain.
If the toilet does not flush when the lift rod is raised, remove
some of the slack in the flapper chain by:
• Relocating the flapper chain S-hook to the top hole in the lift rod.
• Repositioning the flapper chain S-hook on the flapper chain.
Kohler Co.
Tubing
Adjusting the Water Level
7
Waterline
1021796-2-B

Advertisement

loading

This manual is also suitable for:

K-3360K-14230K-3612K-14224