Advertisement

Quick Links

®
T200 HDSL4 H4R Repeater
Installation and Maintenance Guide
Document Number: 61223441L2-5A
CLEI: T1RAAAAB_ _
May 2009

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN T200 HDSL4

  • Page 1 ® T200 HDSL4 H4R Repeater Installation and Maintenance Guide Document Number: 61223441L2-5A CLEI: T1RAAAAB_ _ May 2009...
  • Page 2 In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this About this Document This document provides instructions for the installation and maintenance of the T200 HDSL4 H4R Repeater.
  • Page 3 Revision History Revision Date Description May 2009 Initial release Conventions The following typographical conventions are used in this document: This font indicates a cross-reference link. indicates screen menus, fields, and parameters. This font indicates keyboard keys ( ). Keys that are to be pressed simultaneously HIS FONT NTER are shown with a plus sign (...
  • Page 4 Training ADTRAN offers training courses on our products. These courses include overviews on product features and functions while covering applications of ADTRAN product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at customer sites.
  • Page 5: Table Of Contents

    ADTRAN Technical Support ........
  • Page 6 T200 H4R Capacity Guidelines for ADTRAN Housings ....... . .
  • Page 7: Introduction

    HDSL4 technology provides extended range T1 (DS1) transport on the telecommunications network, and features spectral compatibility with ADSL and other transport technologies. The ADTRAN T200 HDSL4 H4R Repeater (T200 H4R, P/N 1223441L2) regenerates the HDSL4 signal, extending the range of the circuit.
  • Page 8: Description

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice Description Up to three T200 H4R units work in conjunction with an ADTRAN H4TU-C (Central Office Transceiver) and an ADTRAN H4TU-R (Remote) to provide DS1 service on the local loop. • The HRTU-C receives DSX-1 input signals from the network through the chassis, transports them across the circuit, and terminates them through the H4TU-R.
  • Page 9: Electrical Characteristics

    Introduction Electrical Characteristics That following table lists the electrical characteristics of all four input ports of the T200 H4R in an unpowered state. Table 1. T200 H4R Electrical Characteristics Subscriber Loop Test Set Ohmmeter T-GND R-GND T-GND R-GND NET 1 365K 365K NET 1...
  • Page 10: Compliance

    Voltages up to –200 VDC with respect to ground and between individual telecommunications conductors may be present. The T200 HDSL4 H4R Repeater is NRTL Listed to the applicable UL standards. The T200 H4R meets or exceeds all the applicable requirements of NEBS, Telcordia GR-63-CORE, and GR- 1089-CORE.
  • Page 11 Introduction The Chassis frame ground terminal must be connected to an earth ground to ensure that the front panel of the T200 H4R is properly grounded via the backplane connector. Per GR-1089-CORE, the T200 H4R is designed and intended for installation as part of a Common Bonding Network (CBN).
  • Page 12: Compatibility

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice Compatibility The T200 H4R is used in conjunction with any T1.418-compliant, span-powering H4TU-C and H4TU-R. Table 3 list the compatible ADTRAN HDSL4 transceiver units. Table 3. T200 H4R-Compatible ADTRAN HDSL4 Transceiver Units...
  • Page 13: Installation

    Shipping Contents The contents include the following items: • T200 HDSL4 H4R Repeater (P/N 1223441L2) • T200 HDSL4 H4R Repeater Job Aid (P/N 61223441L2-22) • T200 HDSL4 H4R Repeater Compliance Notice (P/N 61223441L2-17) Installing the Module The T200 H4R is designed for deployment in any Type 200 form-factor enclosure. When installing the T200 H4R, refer to the appropriate Installation and Maintenance Guide for the housing being used.
  • Page 14: Front Panel Leds

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice Front Panel LEDs The T200 H4R provides front panel LEDs that display status information. Table 4 lists the T200 H4R LEDs and status descriptions. Table 4. T200 H4R Front Panel LEDs Label...
  • Page 15: Operational Feature Details

    200 ms can be bridged. Bad Splice Detection This T200 H4R supports the Runtime TScan 2.0™ bad splice detection feature, an ADTRAN proprietary, non-intrusive algorithm for detection of anomalies (bad splices) in the copper plant. This feature monitors the cable pair during runtime for the presence of bad splices that can potentially impact service.
  • Page 16: View Splice Results Screen

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice Splices that are varying in impedance cause the HDSL data pump to see a reduced and/or fluctuating signal quality (margin). The HDSL data pump attempts to track these changes. When the changes become too severe, errors or loss of synchronization result.
  • Page 17: Fast Retrain

    Operational Feature Details Fast Retrain Fast Retrain is an ADTRAN-proprietary feature that minimizes downtime when an inter- mittent, non-power related impairment (bad splice, noise burst, etc.) affects the HDSL loop and cannot be bridged. When such an impairment occurs after achieving HDSL synchronization, Fast Retrain restores service within five to seven seconds.
  • Page 18: Ground Fault Or Short Detection

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice Ground Fault or Short Detection If a short or ground fault is detected, the T200 H4R will keep the relays open and continue to monitor the customer side interface until the fault condition clears. During the fault condition, the network-side of that repeater can function normally, allowing for synchroni- zation and loopback/sectionalization testing up to that repeater.
  • Page 19: Connections

    Operational Feature Details Connections All connections are through card edge connectors. Table 5 lists the card edge pin assign- ments. NOTE The T200 H4R dissipates a maximum of 5.4 watts. Ensure that the chassis ground is securely connected to the apparatus case.
  • Page 20: Hdsl4 Deployment Guidelines

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice HDSL4 Deployment Guidelines Refer to the applicable H4TU-C installation and maintenance guide, HDSL4 Deployment Guidelines section, for loop parameters, including attenuation and loop resistance consider- ations. NOTE The H4TU-C with part numbers 1221401L6, 1221403L6, and 1221404L6 support only one T200 H4R in the HDSL4 circuit.
  • Page 21: T200 H4R Capacity Guidelines

    The T200 H4R is designed for installation in a prewired Type 200 or Type 400 enclosure. Table 6 defines the capacity guide- lines for deployment. The housing capacity numbers are based on test results. Table 6. T200 H4R Capacity Guidelines for ADTRAN Housings Part Number Description CLEI Code Slots...
  • Page 22: Maintenance

    T200 HDSL4 H4R Repeater Installation and Maintenance Practice MAINTENANCE The T200 H4R requires no routine maintenance for normal operation. Do not attempt repairs in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the “Appendix A, Warranty”...
  • Page 23: Specifications

    Specifications SPECIFICATIONS Table 7 lists the specifications for the T200 H4R. Table 7. T200 H4R Specifications Specification Description Environmental Operating Temperature: –40°C to 70°C Storage Temperature: –40°C to 85°C Relative Humidity: 95 percent maximum at 50°C, noncondensing Maximum Current Draw: 0.025 A maximum at –48VDC Maximum Heat Dissipation: 1.21 watts...
  • Page 24 T200 HDSL4 H4R Repeater Installation and Maintenance Practice Table 7. T200 H4R Specifications (Continued) Specification Description Tests Diagnostics: Loopback initiated with in-band codes or from H4TU-C or H4TU-R craft interface Compliance UL 60950 NEBS Level 3 (SR-3580) FCC 47CFR Part 15, Class A...
  • Page 25: Warranty And Customer Service

    Appendix A Warranty WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. Refer to the following subsections for sales, support, Customer and Product Service (CAPS) requests, or further information.
  • Page 26 ® Carrier Networks Division 901 Explorer Blvd. Huntsville, AL 35806...

Table of Contents