6. Main components
Service Manual:
MSWM15043 EN
Service Manual
SPA WASHING MACHINES (TKD)
Inlet valves
Supply voltage: 230 V.
Impedance: ≈ 3 - 6 KΩ.
Drain pump
Supply voltage: 230 V
Impedance: ≈ 150 - 250 Ω.
Heating element
Supply voltage: 230 V
Rated power: 1800W
Resistance: ≈ 20-35 Ω.
Dryer heating element
Supply voltage: 230 V
Rated power: 1200W
Resistance: ≈ 40-55 Ω.
Temperature sensors
Resistance: ≈4'8 KΩ at 25ºC