Download Print this page

Goodman GPG13M Specifications page 22

2- to 5-ton c packaged gas/electric units 13 seer / 80% afue
Hide thumbs Also See for GPG13M:

Advertisement

P
s
rodUct
Pecifications
5
w
d
— gPg1324-42m41
iring
iagram
CONNECTED AT L1, L2
11.250±.125
L1
CC T1
L1
L1
1
FUSE
4
5
9
R
TO THC
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
STATUS LIGHT
2 BLINKS
3 BLINKS
4 BLINKS
5 BLINKS
6 BLINKS
22
4
Y
S
R
C
BL
BL
B
COMP
BL
B
CH OPTIONAL
NOTE 3
PU
BR
B
CM
R
CAP2
NOTE 4
LS
BR
R
BR
PU(L2)
R
LOW
EM
BL
MEDIUM
B
HIGH
1
2
3
4
5
EM
PU
BR
3 SPEED
OPTIONAL
R
Y
CAP.2
BL
B
ALT. 3 SPEED
PU
MOTOR
4 SPEED
MOTOR
ALS
PU
PS
Y
PU
Y
G
NOTE 5
Y
RS
Y
3
6
BL
2
5
1
4
PL
PU
PU
SEE NOTE 5
Y
W. R.
(ALT.) HONEYWELL
GAS VALVE
GAS VALVE
PU
R
W
MV
PU
Y
BL
G
GV
GV
BL
BL
MV
Y/Y2
Y1
C R
W G
TO THC
(SEE THC FIELD WIRING BELOW)
VM
IGN
O
FS
R
PU
R
PU
L2
SUPPLY VOLTAGE
208-230/1/60
CH
NOTE 3
T2
R
L2
C
C
COMP
CC
S
H
CAP1
CAP 2
F
CM
NOTE 4
(HIGH)
L1
C
L2
(LOW)
EM
L1
H
L1
D1
VM
L2
TRANS
L2
NOTE 2
2
IGN
FS
FS
LS
ALS
RS
3
GV
IIC
6
PS
8
ECON
7
10
12
CC
11
HPS
NOTE 5
6 5
4
PL
3
2
1
G
W
Y1
Y/Y2
C
INSTALLER/SERVICEMAN
EQUIP. STATUS
CHECK
ON
NORMAL OPERATION
-
OFF
NO POWER OR
CHECK INPUT POWER
INTERNAL CONTROL
CHECK FUSE ON CONTROL
FAULT
REPLACE CONTROL
IGNITION FAILURE
GAS FLOW
1 BLINK
OR
GAS PRESSURE
GAS VALVE
OPEN ROLLOUT
SWITCH
FLAME SENSOR
OR
FLAME ROLLOUT
OPEN AUX. LIMIT
BAD SWITCH
SWITCH
AUX. LIMIT OPEN
PRESSURE SWITCH
CHECK
OPEN
PRESSURE SWITCH
PRESSURE SWITCH CLOSED
CHECK
WITHOUT INDUCER ON
PRESSURE SWITCH
OPEN LIMIT SWITCH
MAIN LIMIT OPEN
BAD SWITCH
FALSE FLAME SENSED
STICKING GAS VALVE
COMPRESSOR
3 MIN. COMP.
OUTPUT DELAY
ANTI-CYCLE TIMER
5.000±.125
www.goodmanmfg.com
3
R
R
B
PU
GRD
B
T1
T2
R
Y
BL
L1
CC L2
B
B
CH OPTIONAL
B
POWER SUPPLY
208-230/1/60
SEE NOTE 6
1
2
3
B
PU
C
208
240
NOTE 2
TRANS
24V
BL/PK
PU
BL
R
BL/PK
GR
Y
BL
Y
R
B
B
ECON
FS
IIC
O
BL
R
Y
R
R
B
PU
PU
NOTE 4
CAP
F
H
C
R
BR
Y
COMPONENT LEGEND
ALS AUXILLARY LIMIT SWITCH
WIRE SPLICE
CAP CAPACITOR
MARKED TERMINAL
COMP COMPRESSOR
UNMARKED TERMINAL
CM CONDENSER MOTOR
WIRING
CC CONTACTOR
LINE VOLTAGE
CH CRANKCASE HEATER
LOW VOLTAGE
EM EVAPORATOR MOTOR
FIELD INSTALLED POWER
FS FLAME SENSOR
FIELD INSTALLED CONTROL
GV GAS VALVE
IIC INTEGRATED IGNITION CONTROL
WIRE CODE
IGN IGNITOR
B
BLACK
LS LIMIT SWITCH
BL BLUE
PL PLUG
BR BROWN
PS PRESSURE SWITCH
G
GREEN
RS ROLLOUT SWITCH
O
ORANGE
PK PINK
THC THERMOSTAT HEAT & COOL
PU PURPLE
TRANS TRANSFORMER
R
RED
VM VENT MOTOR
W
WHITE
HPS HIGH PRESSURE SWITCH
Y
YELLOW
BL/PK
BLUE/PINK
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. CRANKCASE HEATER (OPTIONAL).
4. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING
SPEED AT COOL TERMINAL (IIC). CHANGE HEATING SPEED AT HEAT
TERMINAL (IIC)
4 SPEED MOTOR
3 SPEED MOTOR
B - HIGH SPEED
B - HIGH SPEED
BL - MEDIUM HIGH SPEED
BL - MEDIUM SPEED
Y - MEDIUM LOW SPEED
R - LOW SPEED
R - LOW SPEED
5. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING
IN RETURN AIR COMPARMENT.
6. USE COPPER WIRE
208-230/1/60
THC-FIELD WIRING
2 STAGE COOLING WITH ECONOMIZER
THC-NO ECONOMIZER
W
W
W
W
G
G
G
R
R
R
PU
Y1
Y
Y
Y
Y2
BL
C
BL
0140G01233 REV. A
ECN
REV
A
0904067
Y
Y
Y
G
R
C
SS-GPG13M
2
ZONE
-
INITIAL RELE
THE GOOD
C

Hide quick links:

Advertisement

loading