7.
Mount base and plate to concrete using
mounting holes drilled previously (Mounting
Hardware by Others). Minimum 1/4" diameter
sleeve or wedge anchors for concrete must be
used.
INSTALLATION OF IN-USE RECEPTACLE (RE1 & RE2 Option)
LINE
Receptacle
COM
GROUND
GROUND
BASE
WIRING DIAGRAM
1.
Pull branch circuit wiring. Make watertight
connections from primary branch circuit
to in-use receptacle using waterproof wire
connectors. Connect incoming ground and
ground from receptacle to ground wire on
base. See wiring diagram.
DATA
RJ45
4. Receptacle cover has captive #6-32 screw.
Secure receptacle by tightening captive #6-32
set screw using a 7/64" allen wrench.
Receptacle cover has two (2) openings for
in-use cord sets.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
8. Tighten four (4) #10-32 screws in base using a
3/32" allen wrench to secure to installed PVC
housing.
In-Use
2. Attach ground from branch circuit to screw
on anchor base. Place connectors inside
receptacle.
In-Use
Receptacle
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
Receptacle Bollard
9. Seal base and plate as per NEC. Continue with
installation of In-Use Receptacle option chosen.
3. Attach in-use receptacle to installed anchor
base with four (4) #10-32 button head stainless
steel cap screws at the base using a 1/8" allen
wrench.
RELEASE DATE
REFERENCE NUMBER
12/21/2021
INS-2701-00