Japanese. To change language, select lan-
guage desired and press the ENTER key.
2.5

Units Menu

Units
Depth
Temp
Fish Size
Speed
Wind
Distance
/
/
/
[ENTER]
[MENU]
Units menu
Depth: Choose unit of depth measurement
from m, ft, fa, pb or HR (Japanese).
Temp: Choose unit of temperature measure-
ment from ° C or ° F. Temperature data is
required.
Fish Size: Choose unit of fish size measure-
ment from inch or cm.
Speed: Choose unit of speed measurement
from kt, km/h or mph. Speed data is required.
Wind: Choose unit of wind speed measure-
ment from kt, km/h, mph or m/s. Wind speed
data is required.
Distance: Choose unit of distance measure-
ment from nm, km or sm.
2.6

Calib Menu

Calibration
Draft
Gain ADJ 200 : + 0
Gain ADJ 50 : + 0
Temp
Speed (STW) : + 0%
Fish Size
Water Type
/
/
/
[ENTER]
[MENU]
Calib menu
Draft: The default depth display shows the
distance from the transducer. If you would
rather show the distance from the sea sur-
face, set your ship's draft (setting range: -15.0
to +50.0 ft).
: ft
: °F
: inch
: kt
: kt
: nm
: Select
: Enter
: Back
: + 0.0 ft
: + 0.0 °F
: + 0%
: Salt
: Select
: Enter
: Back
Gain ADJ 200, Gain ADJ 50: If the gain is too
high or too low, or the gain for the low and
high frequencies appears unbalanced, you
can compensate it (setting range: -20 to +20).
Temp: If the water temperature indication has
error, you can correct it here. For example, if
the water temperature indication is 2 ° higher
than actual water temperature, enter -2. The
setting range is -20.0 to +20.0 ° F.
Speed (STW): If the speed indication has
error, you can correct it here. For example, if
the speed indication is 10 % lower than actual
speed, enter +10. The setting range is -50 to
+50 %.
Fish Size: Compensate for wrongful indica-
tion of fish size (setting range: -80 to +100 %).
Compensation size
Double
1.5
1/2
1/3
1/4
1/5
Water Type: Choose the water type with
which to use the FCV-620/585, from Salt or
Fresh. Choose correct water type to get accu-
rate depth data.
2.7

Demo Menu

Demonstrate
/
[ENTER]
[MENU]
Demo menu
Demonstrate: The demonstration mode pro-
vides, without connection of the transducer,
simulated operation of the equipment, using
internally generated echoes. All controls are
operative. The message "DEMO" appears at
the bottom right corner on the screen when
the demonstrate mode is active.
Off: Turn demo mode off.
Demo1: Shallow depth demonstration
Demo2: Deep depth demonstration
21
2. SYSTEM MENU
Setting value
+100 %
+50 %
-50 %
-65 %
-75 %
-80 %
Demonstrate