Hdsl Deployment Guidelines; Figure 15. Hdsl Deployment Guidelines; Table E. Hdsl Loss Values; Table F. Loop Insertion Loss Data - ADTRAN AHT1U Installation & Maintenance

Low voltage asynchronous htu-c line card for dsc communications corporation litespan channel bank assemblies
Hide thumbs Also See for AHT1U:
Table of Contents

Advertisement

6. HDSL DEPLOYMENT GUIDELINES

The ADTRAN HDSL system is designed to provide
DS1-based services over loops designed to comply
with carrier service area (CSA) guidelines. CSA
deployment guidelines are given below.
1. All loops are non-loaded only.
2. For loops with 26-AWG cable, the maximum loop
length including bridged tap lengths is 9 kft.
3. For loops with 24-AWG cable, the maximum loop
length including bridged tap lengths is 12 kft.
4. Any single bridged tap is limited to 2 kft.
5. Total bridged tap length is limited to 2.5 kft.
6. The total length of multi-gauge cable containing
26-AWG cable must not exceed the following:
26
12 - {(3*L
)/9} - L
L
26
= total length of 26-AWG cable excluding
bridged taps (in kft)
BTAP
L
= total length of all bridged taps (in kft)
This deployment criteria is summarized in the chart
shown in Figure 15.
12
11
INVALID HDSL CABLE LENGTHS
10
9
8
7
6
5
4
3
2
VALID HDSL CABLE LENGTHS
1
0
0
1
2
3
WORKING LENGTH OF 26 GAUGE CABLE (KFT)

Figure 15. HDSL Deployment Guidelines

16
BTAP
(in kft)
TOTAL
BRIDGED
2.5
TAP
2.0
1.5
LENGTH
1.0
(KFT)
0.5
0.0
4
5
6
7
8
Section 61245002L6-5, Issue 3
Loop loss per kft for other wire is summarized in
Table E.

Table E. HDSL Loss Values

(200 kHz cable loss in dB/kft at 135Ω)
Cable Gauge
Cable Type
26
26
24
24
22
22
19
19
Recommended maximum local loop loss information
for PIC cable at 70°F, 135Ω, resistive termination is
provided in Table F.

Table F. Loop Insertion Loss Data

Frequency (Hz)
3000
10,000
50,000
100,000
150,000
196,000
200,000
An approximation for the maximum amount of
wideband noise on an HDSL local loop as measured
by a 50 kbps filter is ≤ 31 dBrn.
An approximation for the maximum level of impulse
noise as measured using a 50 kbps filter on an HDSL
loop is ≤ 50 dBrn.
These approximations are to be used as
guidelines only and may vary slightly on
different loops. Adhering to the guidelines
9
should produce performance in excess of
-7
10
BER.
Temperature
°
°
68
90
PIC
3.902
4.051
Pulp
4.030
4.179
PIC
2.863
2.957
3.159
3.257
Pulp
PIC
2.198
2.255
Pulp
2.483
2.450
PIC
1.551
1.587
Pulp
1.817
1.856
Maximum Loss (dB)
12.0
15.0
25.5
30.0
32.75
35.00
35.25
NOTE
61245002L6-5C
°
120
4.253
4.381
3.083
3.391
2.333
2.629
1.634
1.909