TECHNICAL INFORMATION
SERIAL NUMBER LOCATION
Record the engine serial number, engine type, and date of purchase in
the spaces below. You will need this information when ordering parts
and when making technical or warranty inquiries.
STANDARD TYPES
SERIAL NUMBER &
ENGINE TYPE LOCATION
LOW PROFILE TYPES
SERIAL NUMBER &
ENGINE TYPE LOCATION
Engine serial number: __ __ __ __ — __ __ __ __ __ __ __
Engine type: ___ ___ ___ ___
Date Purchased: ______ / ______ / ______
16
BATTERY CONNECTIONS FOR ELECTRIC STARTER
(applicable types)
Recommended Battery
iGX270/iGX390
Be careful not to connect the battery in reverse polarity, as this will short
circuit the battery charging system. Always connect the positive (+)
battery cable to the battery terminal before connecting the negative (–)
battery cable, so your tools cannot cause a short circuit if they touch a
grounded part while tightening the positive (+) battery cable end.
A battery can explode if you do not follow the correct
procedure, seriously injuring anyone nearby.
Keep all sparks, open flames, and smoking materials away
from the battery.
The battery contains sulfuric acid (electrolyte), which is
highly corrosive and poisonous.
Getting electrolyte in your eyes or on your skin can cause
serious burns.
Wear protective clothing and eye protection when working
near the battery.
KEEP CHILDREN AWAY FROM THE BATTERY.
WARNING: Battery posts, terminals, and related accessories contain lead
and lead compounds. Wash your hands after handling.
1. Connect the positive (+) battery cable to the starter solenoid terminal
as shown.
2. Connect the negative (–) battery cable to an engine mounting bolt,
frame bolt, or other good engine ground connection.
3. Connect the positive (+) battery cable to the battery positive (+)
terminal as shown.
4. Connect the negative (–) battery cable to the battery negative (–)
terminal as shown.
5. Coat the terminals and cable ends with grease.
POSITIVE (+)
BATTERY CABLE
NEGATIVE (–) BATTERY CABLE