Indoor Unit Installation

Hazardous Service Procedures!
The maintenance and troubleshooting procedures recommended in this section of the
manual could result in exposure to electrical, mechanical or other potential safety
hazards. Always refer to the safety warnings provided throughout this manual
concerning these procedures. When possible, disconnect all electrical power including
remote disconnect and discharge all energy storing devices such as capacitors before
servicing. Follow proper lockout/tagout procedures to ensure the power can not be
inadvertently energized. When necessary to work with live electrical components, have
a qualified licensed electrician or other individual who has been trained in handling live
electrical components perform these tasks. Failure to follow all of the recommended
safety warnings provided, could result in death or serious injury.
Mounting Location
1.
2.
3.
Drilling a hole in the wall to install the piping
The piping can be connected in six different locations on the unit, as shown on figure below:
Right
Rear Right
Right Downward
1.
1234-TTT000-EN

Installation

WARNING
Always mount the rear panel horizontally.
Fix the rear panel on the selected location
Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult
of 60kg, furthermore, the weight should be evenly shared by each screw.
Left
Rear Left
Left downward
Drill a 65mm diameter hole in the wall at a slight downward angle toward the outdoor side in
such a way that the end of the pipe outside is 5 mm lower than the inside.
9