Special Accessories; Installation; Unpacking; Placement - Electrolux EFT 600-2 User Manual

Hide thumbs Also See for EFT 600-2:
Table of Contents

Advertisement

Available languages

Available languages

Special accessories

Active carbon filter
When the hood is used in recirculation mode an
active carbon filter should be used.
Order by the retailer
PNC 942 120 388

Installation

Unpacking

Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.

Placement

The hood is to be mounted on the wall or under a
wall cupboard.
When installed, the hood must be not less than
60 cm. above electric burners or 70 cm. above
gas or mixed-fuel burners. (Fig. 4).

Electrical connection

The hood has a power cord with moulded plug
with earth connection to be connected to a wall
outlet of 230 V.
The power cord length is 1 m.
Mounting under cupboard
Make the holes on the bottom of the cupboard.
From inside the cupboard, insert the 4 supplied
screws and tighten them in the appropriate
holes on the appliance (Fig. 5).
Attention!
Mounting screws are located in the box beside
the conveyor.
32
Min
60 cm
Fig. 4
Fig. 5
Min
70 cm