Briggs & Stratton P4500 Manual
Hide thumbs Also See for P4500:

Advertisement

(030806-00, 030806-01)
Copyright © 2021. Briggs & Stratton
Milwaukee, WI, USA. All rights reserved.
BRIGGSandSTRATTON.com
P4500
en - English
ar - ‫العربية‬
bg - български език
cs - Čeština
da - Dansk
de - Deutsch
el - Ελληνικά
es - Español
et - Eesti keel
fi - Suomi
fr - Français
hr - Hrvatski
hu - Magyar
it - Italiano
lt - Lietuvių k.
lv - Latviešu
nl - Nederlands
no - Norsk
pl - Polski
pt - Português
ro - Română
ru - Pусский
sk - Slovenčina
sl - Slovenščina
sv - Svenska
sw - Kiswahili
tr - Türkçe
Manual No. 80101782 Rev B

Advertisement

Table of Contents
loading

Summary of Contents for Briggs & Stratton P4500

  • Page 1 P4500 (030806-00, 030806-01) en - English ar - ‫العربية‬ bg - български език cs - Čeština da - Dansk de - Deutsch el - Ελληνικά es - Español et - Eesti keel fi - Suomi fr - Français hr - Hrvatski...
  • Page 2 BRIGGSandSTRATTON.COM...
  • Page 4: Table Of Contents

    Table of Contents Equipment Description Read this manual carefully and become Safety and Control Symbols ....4 familiar with your outdoor generator. Know Equipment Description .
  • Page 5: Features And Controls

    Features and Controls Figure Operation Step 1: Safe Location Retractable Handle 12 Volt DC Receptacle Activate Switch Grounding Fastener Before starting the portable generator there are two equally important safety concerns regarding carbon Low Oil Indicator Q 230 Volt AC, 16 Amp monoxide poisoning and fire that must be addressed.
  • Page 6 Operation Location to Reduce the Risk of Fire Add Fuel Figure WARNING! Exhaust heat/gases could Fuel must meet these requirements: ignite combustibles, structures or • Clean, fresh, unleaded gasoline with a minimum of damage fuel tank causing a fire, 91 RON (87 octane/87 AKI). resulting in death or serious injury.
  • Page 7 Step 3: Generator Start up Figure 1 3 9 QPT™ (QUIET POWER TECHNOLOGY™) Figure Disconnect all electrical loads from the generator. Use This feature improves fuel economy. When QPT switch the following start instructions: (E) is turned ON, the engine speed will increase as 1.
  • Page 8 Carbon Monoxide (CO) Shutdown System 230 Volt AC, 16 Amp Receptacles Figure Figure Use receptacles (Q) to operate 230 Volt AC, single– phase, 50 Hz electrical loads requiring up to 3,680 watts Automatically shuts down the engine when harmful levels (3.68 kW) at 16 Amps of current.
  • Page 9: Maintenance

    Maintenance Battery Maintenance Figure The generator is equipped with an automatic battery Maintenance Schedule charging circuit that charges the battery while the Follow hourly or calendar intervals, whichever occurs engine is running. If the generator isn’t used frequently, first. More frequent service is required when operating in the battery should be connected to a trickle charger adverse conditions.
  • Page 10: Storage

    Storage Service Spark Plug Figure 1 10 11 Changing the spark plug will help your engine to start If storing the unit for more than 30 days, use the following easier and run better. guidelines to prepare it for storage. 1.
  • Page 11: Troubleshooting

    Troubleshooting Problem Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Poor connection or defective cord set. 2. Check and repair. 3. Connect another device that is in 3. Connected device is bad. Engine is running, but no AC good condition.
  • Page 12 BRIGGSandSTRATTON.COM...
  • Page 13: Warranty

    BRIGGS & STRATTON PRODUCTS WARRANTY POLICY Limited Warranty Briggs & Stratton warrants that, during the warranty period specified below, it will repair or replace, free of charge, any part that is defective in material or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for and is subject to the time periods and conditions stated below.