Bosch DS9360 Installation Manual page 3

Tritech ceiling mount pir/microwave detector

Advertisement

Available languages

Available languages

NOTICE!
Be sure all wiring is de-energized before routing.
4. Firmly mount the base. Depending on local regulations, the base may
be directly surface mounted using anchors, mollies, or wing-nuts, or
may be mounted to standard 4-inch octagonal or square electrical
boxes.
NOTICE!
The DS9360 base will not completely cover a 4-inch square box. Where
aesthetics are important, a 4-inch octagonal box is recommended.
NOTICE!
Mounting to removable ceiling tiles is not recommended unless a
sandwich is made of the base, ceiling tile, and a back plate behind the
tile. Covers used for 4-inch octagonal and square boxes make a suitable
back plate (when used with bolts and wing nuts, as an example).
REAR WIRE
TERMINAL
STRIP
ENTRANCE
WIRE
TIE-DOWNS (2)
MOUNTING
INTERFACE
SLOTS (4)
PINS
Mounting Base
Figure 2.2: Mounting
3 Wiring
CAUTION!
Only apply power after all connections have been made and inspected.
Do not coil excess wiring inside detector. Use no smaller than #22
AWG (0.8 mm) wire in the terminal strip.
POWER
-
+
-
+
Figure 3.1: Wiring to terminals
5 © 2021 Bosch Security Systems B.V.
Anti-vandal Screw Hole
LED and
LED Jumper
Sensitivity
Jumper
LED
OFF ON
I
H
Wires
To
Cover
MIN
Microwave
Adjustment
Anti-vandal Screw Hole
LED
Top View of Enclosure
ALARM
TAMPER
NO
C
NC
T
T
TR
Terminals 1 (-) & 2 (+): Power contacts.
Terminals 3 (NO), 4 (C), & 5 (NC): Alarm relay contacts. Use terminals 4
& 5 for Normally Closed circuits. Do not use with capacitive or inductive
loads.
Terminals 6 (T) & 7 (T): Normally Closed tamper contacts.
Terminal 8 (TR): Solid state Trouble output. Shorts to ground (-) when the
detector is in a Trouble condition.
4 Coverage
360° by 60 ft. (18.3 m) diameter coverage when mounted on 8 to 18 ft
(2.4 to 5.5 m) high ceilings.
The coverage pattern consists of 64 zones grouped into 16 barriers,
with one additional zone looking straight down from the unit
(sabotage). Each barrier is 30 ft (9.2 m) long and 4.4 ft. (1.3 m) wide
at 30 ft (9.2 m).
The DS9360 comes with a choice of two optical modules. Refer to
Section 5.1 to determine the best module for on ceiling height.
30 ft
26 ft
20 ft
13 ft
7 ft
0 ft
7 ft
13 ft
20 ft
9 m
8 m
6 m
4 m
2 m
0 m
2 m
4 m
6 m
8 m
9 m
8 m
6 m
4 m
2 m
0 m
2 m
4 m
6 m
9 m
5 Optical Module
5.1 Selecting the Optical Module
1. For ceilings between 8 and 13 ft. (2.4 and 4.0 m) from the floor, use
the optical module marked AR8-13. This marking can be found next to
the two optical module tabs.
2. For ceilings between 13 and 18 ft. (4.0 and 5.5 m) high, use the optical
module marked AR13-18.
3. To replace an optical module, push the optical module tabs towards
the center until the module snaps free of the circuit board. Holding the
new module by the tabs, snap the new module into place.
4. Replace the enclosure onto the base.
5. Close cover and turn clockwise to secure.
NOTICE!
Avoid fingerprints on the mirrored surfaces. Should the mirrored sur-
faces become soiled or otherwise marked, they can be cleaned using a
soft, clean cloth and any commonly available, mild window cleaner.
30 ft
26 ft
30 ft
26 ft
≤5.5 m
≤18 ft
20 ft
4.6 m
AR13-18
15 ft
≥4.0 m
≥13 ft
13 ft
7 ft
0 m
0 ft
0 ft
7 ft
≤4.0 m
≤13 ft
3.0 m
AR8-13
10 ft
≥2.4 m
≥8 ft
13 ft
20 ft
0 m
0 ft
8 m
6 m
4 m
2 m
0 m
2 m
4 m
6 m
8 m
9 m
9 m
26 ft
30 ft
8 m
9 m
F.01U.263.664 | 08 | 2021.04 | 6