Sharp AR-5132 Service Manual page 175

Hide thumbs Also See for AR-5132:
Table of Contents

Advertisement

Main
Sub
Item
code
code
52
03
Sets ADU drive
clutch OFF time.
53
RADF
adjustment.
01
Adjusts RADF
stopping
position (normal
paper, face
side).
ADU drive clutch OFF time:
The ADU drive clutch OFF time increases 10 ms for every "+1" in adjustment value.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-9]:
Enters new settings.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
SIMULATION No.53- _
1.RADF STOP POSITION ADJUSTMENT
(PLAIN PAPER/ONE SIDE)
2.RADF STOP POSITION ADJUSTMENT
(PLAIN PAPER/BOTH SIDE)
5.RADF RESIST SENSOR ADJUSTMENT
6.RADF REPULSION SENSOR ADJUSTMENT
7.RADF TIMING SENSOR ADJUSTMENT
INPUT SUB NO. AND PRESS PRINT SWITCH
SIMULATION No.53- 1
RADF STOP POSITION ADJUST VALUE SETUP
PLAIN PAPER/ONE SIDE[XX]:_
(0~15)
INPUT SETUP VALUE AND PRESS PRINT_SW
[Content] The adjustment value of the RADF document stopping position can be set. The
current setting is displayed and a new setting can be entered.
RADF stopping position (normal paper face side):
The stopping position increases 1 mm for every 1 marking of adjustment value.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-9]:
Enters new settings.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
Content
Adjustment range
0 ∼ 10
Adjustment range
0 ∼ 15
9 – 79
Adjustment
range
9-15