Step 11 - Install Unit Drain Line - Carrier 90MA Installation, Operating & Service Instructions

Single-package marine cooling units
Table of Contents

Advertisement

TABLE 3 - RECOMMENDED LINE SIZES (INCHES) REMOTE CONDENSERS
UNIT
REFRIGERANT
90MU
TYPE
404
R-407C
406
R-407C
408
R-407C
412
R-407C
504
R-404A
506
R-404A
508
R-404A
512
R-404A
NOTES:
1. Pipe sizes should never be smaller than cooling unit connection size.
2. Table is based on 2 degree F drop over entire length. Excessive (more than a few) elbows
and fittings will significantly affect pressure drop. If this situation exists, line sizing must be re-
calculated.
Step 11 - Install Unit Drain Line - Install a trapped
condensate drain line at unit drain connection The drain
requires standard pipe connected to condensate pan
nipple(s). Figure 7 shows proper trap design.
Determine design negative static pressure. This
pressure is not the same as fan total static pressure, which
includes pressure losses downstream as well as upstream
from the evaporator air fan. Always assume the worst
conditions, such as having return air filters clogged with
debris.
Referring to Figure 7, differential 1 must be equal to or
larger than negative static pressure at design operating
condition. Store enough water in trap to prevent losing
seal. Differential 2 must be equal to or larger than one-half
the maximum negative static pressure. To avoid loss of
seal when the fan starts, differential 3 must be greater
than the maximum negative static pressure.
Do not use drain line smaller than 3/4 inch. Use hole(s)
provided in panel for drain line. Pitch drain line downward
toward scupper. Installation of a plugged tee is
recommended for cleaning. Fill trap with water to make an
air seal. Observe all sanitary requirements.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations
Printed in U.S.A.
0-25
DISCH
LIQUID
DISCH
1/2
3/8
5/8
3/8
3/4
1/2
7/8
1/2
5/8
3/8
3/4
1/2
7/8
1/2
7/8
5/8
1-1/8
* Recommended line sizes correspond to 2 degree F drop.
LENGTH OF RUN
26-50
LIQUID
DISCH
5/8
3/8
5/8
3/4
3/8
3/4
3/4
1/2
7/8
7/8
1/2
7/8
5/8
3/8
3/4
3/4
1/2
7/8
7/8
1/2
1-1/8
5/8
1-1/8
FIGURE 7 - CONDENSATE DRAIN TRAP
90MA-3SI
SUPERCEDES FORM 62-02971-00 09-2009
Pg 11
51-75
76-100
LIQUID
DISCH
3/8
5/8
3/8
3/4
1/2
7/8
1/2
1-1/8
3/8
3/4
1/2
7/8
1/2
1-1/8
5/8
1-1/8
LIQUID
3/8
3/8
1/2
5/8
3/8
1/2
5/8
5/8