Calculating The Total Ducting Length - Miele PDR 307 EL CC Operating And Installation Instructions

Vented dryer
Table of Contents

Advertisement

Calculating the total ducting
length
The entire ducting system (including
bends and components) generates air
resistance that pushes against the ex-
haust air. The relative pipe lengths and
total ducting length have to be calcu-
lated for this reason:
- The  relative pipe length (table I)
indicates how much greater the air
resistance of a bend is, for example,
when compared to 1 metre of a
straight plastic waste water pipe.
- Adding all of these relative pipe
lengths together gives the  total
ducting length. This is not the actual
length but a calculated figure. The
total ducting length (table II) ex-
presses the air resistance of the en-
tire exhaust air system.
Because a larger  pipe diameter (ta-
ble II) reduces the air resistance, a
longer total duct length requires a
greater pipe diameter.
Procedure
 Measure the length needed for the
straight sections of ducting. Multiply
the length by the corresponding rel-
ative pipe length from table I.
 Calculate the number of bends and
elbows needed. Use table I to help
you add together their relative pipe
lengths.
 Calculate the total duct length: add
together all of the relative pipe
lengths calculated under  and .
 Refer to table II for the pipe diameter
needed for the total duct length.
Installation of the ducting
Table I
Components
Exhaust air hose (highly flexible)*
1 m, laid straight
45° bend (radius of bend = 0.25 m)
90° bend (radius of bend = 0.25 m)
Exhaust air hose (flexible or flex-
ible aluminium)*/plastic waste
water pipe
1 m, laid straight/straight pipe
45° bend (radius of bend = 0.25 m)
90° bend (radius of bend = 0.25 m)
Wall pipe* or window connection*
With inserted grille
With non-return flap (swinging flap)
Non-return flap* for integration
into the ducting
(see "Shared exhaust air duct")
Flat ducting (for stacked installa-
tion)*
* Optional accessories
Table II
 Total duct length
Maximum of 20 m
Maximum of 40 m
Maximum of 80 m
 Relat-
ive
pipe
length
1.8 m
1.5 m
2.5 m
1.0 m
0.6 m
0.8 m
3.8 m
1.5 m
14.3 m
11.0 m
 Pipe diameter
100 mm
125 mm
150 mm
57

Advertisement

Table of Contents
loading

Table of Contents