Ethernet 1 Port Connection
If the ONT is going to support up to 1 Gigabit operation (10/100/1000), the 
cable used should be rated CAT‐6. If an ethernet cable is not available, 
use the Ethernet RJ‐45 Pin‐Out table below and strip back the jacket of the 
subscriber Ethernet cable and connect the 4‐pair twisted wires to the RJ‐45 
Plug using an RJ‐45 crimper. 
Insert the terminated RJ‐45 jack into the appropriate RJ‐45 
socket on the SFU ONT. Refer to the illustration on the first page for these 
connections.
Ethernet 1 Port RJ-45 Pin-Out
Pin
Name
1
TRD0+
Transmit/Receive Positive
2
TRD0‐
Transmit/Receive Negative
3
TRD1+
Transmit/Receive Positive
4
TRD2+
Transmit/Receive Positive
5
TRD2‐
Transmit/Receive Negative
6
TRD1‐
Transmit/Receive Negative
7
TRD3+
Transmit/Receive Positive
8
TRD3‐
Transmit/Receive Negative
O
S
PERATIONAL
PECIFICATIONS
Voltage Range: 10.5 to 15 VDC
Maximum Current: 1.5 Amps 
Operational Temperature Range: –40°C to +65°C
Storage Temperature Range: –40°C to +85°C
Relative Humidity: 95%, noncondensing
Dimensions: 9.7"W x 12"H x 4"D (25 cm x 30 cm x 10 cm)
Weight: 3 lbs 0.8 oz. (1.6 kg), enclosure and electronics module 
M
AINTENANCE
The SFU ONT does not require routine hardware maintenance for normal 
operation. ADTRAN does not recommend that repairs be attempted in 
the field. Repair services may be obtained by returning the defective unit 
to ADTRAN. Refer to the warranty for further information. Field support 
for software is provided through upgrade facilities.
S
R
AFETY AND
EGULATORY
The Total Access 300 Series SFU ONT is NRTL Listed to the applicable UL 
safety standards. The Total Access 300 Series SFU ONTs meet or exceed all 
the applicable requirements of NEBS, and Telcordia GR‐63‐CORE. 
The Total Access 300 Series SFU ONT is intended for deployment in the 
Outside Plant (OSP) at locations where the NEC applies (for example, 
Customer Premises) and is intended to be installed by trained service 
personnel. Configuration Codes for the SFU ONT are listed below.
Configuration Codes
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
For more information, refer to the Installation and Maintenance Practice (P/N 64187712G2-5)
available online at www.adtran.com.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
1
ETH
Port 
Description
Color Code
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
C
OMPLIANCE
Input
Output
F
A
This device complies with Part 15 of the FCC rules. Operation is subject to 
the following two conditions:
1. This device may not cause harmful interference. 
2. This device must accept any interference received, including 
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could 
void the user's authority to operate this equipment.
!
WARNING
The 10/100/1000 Base‐T port(s) and POTS are classified as Type 4 as
defined in Appendix B of GR‐1089‐CORE Issue 4, and are suitable for
connection to intra‐building or unexposed wiring or cabling only. Do not
metallically connect these ports to interfaces which connect to the Outside
Plant (OSP) or to the OSP wiring. The 10/100/1000 Base‐T ports and POTS
are designed for use as an intra‐building interface only (Type 4 ports as
described in GR‐1089‐CORE Issue 4) and require isolation from exposed
OSP cabling. The addition of Primary Protectors is not sufficient
protection in order to connect this interface metallically to OSP wiring.
C
CAUTION
The Total Access 300 Series SFU ONTs contain a Class 1 Laser Module that
complies with 21 CFR 1040.10 and 1040.11.
!
CAUTION
Electrostatic Discharge (ESD) can damage electronic modules. When
handling modules, wear an antistatic discharge wrist strap to prevent
damage to electronic components. Place modules in antistatic packing
material when transporting or storing. When working on modules,
always place them on an approved antistatic mat that is electrically
grounded.
This equipment must be connected to a known, reliable earth ground
at all times during installation and service. Refer to the National
Electrical Code (NEC) and state/local codes for details on grounding
requirements. A 6 AWG copper ground conductor shall be used to
connect the equipment to earth ground.
Per GR‐1089‐CORE the Total Access 300 Series SFU ONTs are designed
and intended for installation as part of a Common Bonding Network
(CBN). The Total Access 300 Series SFU ONT are not designed nor
intended for installation as part of an Isolated Bonding Network
(IBN).
Per GR‐1089‐CORE Section 9, the SFU ONTs do not have an internal
DC connection between 12V and frame ground. 
The Total Access 300 Series SFU ONTs Chassis frame ground terminal
must be connected to an earth ground to ensure the ONT SFU is
properly grounded.
NOTE
Power supply input and output conductors of equipment which are
outside of the building, are intended to be less that 140 feet and have
adequate  clearance  from  power  and  lightning  conductors  in
accordance with NEC 725 and 800. Final acceptance of the Listed
equipment installation will ultimately be up to the local Authority
Having Jurisdiction (AHJ).
C
The main feed is optical and therefore not classified as any type of port
as defined in Appendix B of GR‐1089‐CORE Issue 4.
The Total Access 300 Series SFU ONTs are designed to operate with
nominal operating voltage of 12 VDC and a minimum operating
voltage of 10.5 VDC. The Total Access 362 will not be damaged by any
steady state voltage between 10.5 VDC and 15.0 VDC in magnitude.
C A U T I O N !
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
ADTRAN CUSTOMER CARE:
From within the U.S.
1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*64187712G2-22C*