ADTRAN Total Access 300 Series Manual
Hide thumbs Also See for Total Access 300 Series:

Advertisement

Quick Links

Product P/N: 4187712G2
Surface Mounting Hole
Hinge
Security
Screw
Hinge
Fiber Optic
Cable
Ground
Fiber Drop
Ground Drop
D
ESCRIPTION
The Total Access
®
362S Single Family Unit (SFU) Optical Network
Terminal (ONT) is a Gigabit Passive Optical Network (GPON) ONT
with RF Overlay and Single Wire Return Device (SWRD) powering
(SFU ONT, P/N 4187712G2). The Total Access 300 Series has 2
POTS, and 2 Ethernet interfaces. The figure above illustrates the
SFU ONT inner enclosure. GPON technology provides a consistent
and common approach to advancing the public communications
network using:
Traditional telephone service [Plain Old Telephone Service (POTS)]
High speed data services (10/100/1000)
Video services 
ETH 2
SWRD powering through 
This Job Aid covers the electronics modules (SFU ONT) and housings 
listed in the following table:
Total Access
Description
362S
1187712G2
Total Access 362S Electronics Module
Total Access
Description
SFU Housings
1187770G1
Total Access ONT Splice Housing
1187771G1
Total Access ONT with OptiTap Housing
NOTE
Refer to the Total Access 300 Series GigE SFU ONT with RF Overlay
and SWRD Powering Installation and Maintenance Guide (P/N
64187712G2-5) for more extensive installation instructions.
Total Access 300 Series
GigE SF ONT
with RF Overlay and SWRD Powering
Two-screw
Terminal
TIP
RING
Bridges
TIP
RING
TIP
RING
FXS 0/1
FXS 0/2
TIP
RING
POTS 2
TIP
RING
TIP
RING
ETH 1
ETH 2
ETH 0/1
ETH 0/2
SWRD Powering
Ethernet
Connections
CLEI
TEL. NUMBER
POTS Drop
RF Connection
Ethernet Drop
Surface
Mounting
Power
Hole
Ground and Power
Drop Callout
 (10/100)
F
P
LED
RONT
ANEL
Label
Status
POWER
Off
Green
NETWORK
Green
STATUS
Yellow
Red
SWRD POWER
Off
(ETH 2)
Green
POTS 1 and 2
Off
Green
2
Green Flashing
ETH 1 and 2
Off
Green
Yellow Flashing
I
NSTALLATION
After unpacking the SFU ONT, inspect it for damage. If damage is noted, 
file a claim with the carrier and then contact ADTRAN. For more infor‐
mation, refer to the warranty.
Required Tools and Supplies
Standard technician tools are used for installing SFU ONT. For a complete 
list of special tools, supplies and test equipment, refer to the Total Access 
300 Series GigE SFU ONT with RF Overlay and SWRD Powering Installation 
and Maintenance Guide (P/N 64187712G2‐5).
Mount the Enclosure
Complete the following steps to mount the enclosure:
1. Choose a vertical surface near an approved ground, but away from 
down spouts, permanent water sprinklers, or other water sources. 
The subscriber should have easy access for testing.
2. Use the top and bottom external mounting holes as a template to 
mark fastener locations. Use a level to ensure the unit is level to 
prevent warping.
3. Pre‐drill the marked locations and install fasteners or anchors 
appropriate to the mounting surface (each anchor rated to 15 lbs 
minimum).
4. Mount the SFU ONT to the side of the subscriber's premise.
The Electronics Module is installed in the housing and swings open on 
hinges. To release this module, loosen the Security Screw (refer to the 
illustration on the first page) and swing the electronics Module to the left.
!
CAUTION
Do not use a knife to cut the opening in the rubber grommets. This may
result in an excessively large hole and compromise the integrity of the
unit allowing moisture into the unit.
jobAid
Issue Date: September 2010
Document P/N: 64187712G2-22C
S
Description
No power
Power is On
OLT has activated the ONT
OLT is discovering and ranging
The OLT has shut down the ONT
Power disabled
Power is On
Fiber is disconnected, GPON inter‐
face is down, or both ports are idle 
or disabled
At lease one port is Off Hook
At least one port is Ringing
Link is down, no activity, or Admin‐
istratively Shut down
Link is up
TX or RX activity
1

Advertisement

loading

Summary of Contents for ADTRAN Total Access 300 Series

  • Page 1 SFU Housings hinges. To release this module, loosen the Security Screw (refer to the  1187770G1 Total Access ONT Splice Housing illustration on the first page) and swing the electronics Module to the left. 1187771G1 Total Access ONT with OptiTap Housing CAUTION Do not use a knife to cut the opening in the rubber grommets. This may NOTE result in an excessively large hole and compromise the integrity of the Refer to the Total Access 300 Series GigE SFU ONT with RF Overlay unit allowing moisture into the unit. and SWRD Powering Installation and Maintenance Guide (P/N 64187712G2-5) for more extensive installation instructions.
  • Page 2 Ground Connection 7. Replace the rubber grommet while closing the Electronics Module.  This places less stress on the wiring and allows the Electronics  Refer to the illustration below and in the opposite column to install the  Module to close without pinching any wiring.  ground connection: Route OptiTap Fiber Drop Cable 1. Remove the rubber grommet from the housing and insert a #6 solid  copper ground wire through the rubber grommet.  Refer to the illustration below for fiber installations: 2. Replace the rubber grommet in the housing. 1. Place the OptiTap fiber drop in the same rubber grommet channel  3. Route the ground wire 12 inches below finished grade by the  as the ground cable. The ground cable should be “behind” the Opti‐ shortest and most direct route to the AC power ground system  Tap fiber.  Multi Grounded Neutral (MGN) of the customer premises. Ensure  2. Connect the OptiTap fiber. the wire is free of any sharp bends. 3. Place the OptiTap connector in the cut‐out in the housing. 4. Attach the ground wire to the side of the subscriber’s premises with  stainless steel half moon clamps or tie‐wrap the ground wire to the  4. Connect the fiber cable to the connector on the bottom of the  riser conduit of the Buried Fiber Drop.  Electronics Module. 5. Clean the MGN connector with emery cloth to insure a stable  5.
  • Page 3 Use the Pin‐Out information in the table below as needed. Pin-Out Description Pin-Out Mounting Points Power/Alarm LOW BAT BAT MIS  2 REP BAT ON BAT SIG RTN Mounting Mounting Point Point 12V RTN +12VDC  Power CAUTION Use caution when routing wires and cables. Avoid severe bending and routing over sharp edges. Use grommets when possible to avoid wear on cable insulation. (Connector Cover, Screw and Rubber Seals removed Earth for illustration purposes) Ground 1. Install the UPS cable that runs from the SFU ONT to the Power/ A: TV/DHCT Port. Starting at the home set-top connect to the data network Alarm Connector of the UPS via the customer provided PVC con‐...
  • Page 4 From within the U.S. 1.800.726.8663 From outside the U.S. +1 256.963.8716 Warranty: ADTRAN will replace or repair this product within the warranty period if it does not PRICING AND AVAILABILITY 1.800.827.0807 meet its published specifications or fails while in service. Warranty information can...