Amana Technical Information—Room Air Conditioner
AAC101SRA
• Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this air conditioner.
• Refer to Service Manual 16022061 for installation, operation, disassembly, testing, and troubleshooting
information.
• Refer to Parts Reference material for part number information.
All safety information must be followed as provided in Service Manual 16022061.
To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and discharge
capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed during
disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Model
Electrical requirements
Refrigerant/amount
Compressor
Voltage low/high (nominal)
BTUH
Watts
Current
Lock rotor
Full load
Overload protector
Fan motor
Electrical requirements
RPM
Low speed
Med speed
High speed
Watts at high speed
Current at high speed
Compressor Capacitor
Capacitance
Voltage rating (nominal)
Fan Motor Capacitor
Capacitance
Voltage rating (nominal)
December 2002
PAAC101SRA0
!
!
CAUTION
WARNING
AAC101SRA
115 VAC 60Hz
R22/30 ounces
98/132 VAC (115 VAC)
10,735 BTUH
1000 watts
54 amps
8.8 amps
External
115 VAC 60Hz
730 RPM
830 RPM
1000 RPM
97 watts
2.1 amps
45 Mfd ±10%
250 V
8 Mfd ±5%
450 V
1
16022064
(Replaces RT4110056 Rev. 0)

Advertisement

loading

Summary of Contents for Amana AAC101SRA

  • Page 1 Amana Technical Information—Room Air Conditioner AAC101SRA PAAC101SRA0 • Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this air conditioner. • Refer to Service Manual 16022061 for installation, operation, disassembly, testing, and troubleshooting information.
  • Page 2 https://appliancetechmanuals.com Component Specifications WARNING To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and discharge capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration Component Test Procedure...
  • Page 3 https://appliancetechmanuals.com Component Specifications WARNING To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and discharge capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration Component Test Procedure...
  • Page 4 SWITCH LOW FAN SPEED LOW COOL MID COOL HIGH COOL HIGH FAN SPEED THERMOSTAT COMPRESSOR PROTECTOR CAPACITOR R: RED W: WHITE G: GREEN B: BLACK BL: BLUE BR: BROWN Y: YELLOW AAC101SRA PAAC101SRA0 16022064 December 2002 (Replaces RT4110056 Rev. 0)

This manual is also suitable for:

Paac101sra0