Item
(on the service
remote control)
D2-BRT
D2-CNT
D2-CLR-R
[MENU] → [5]
D2-CLR-B
D2-TNT
D2-SHR
D3-BRT
D3-CNT
D3-CLR-R
[MENU] → [6]
D3-CLR-B
D3-TNT
D3-SHR
DR(C/D1)
[VOL p] → [4]
C-DR(C/D2)
DB(C/D1)
[VOL p] → [6]
C-DB(C/D2)
2. Flicker Adjustment
1. Enter the Service mode. (See page 5-1.)
2. Press [2] button on the remote control unit.
The following screen appears.
VCOM
110
Button
Data
Value
133
140
74
74
128
112
125
138
68
68
128
112
182
159
187
154
3. If Flicker Adjustment is not fit, the screen become
the following.
FLASH (Go and Off)
4. Press [CH o / p] buttons on the remote control
unit so that flash stops.
5-2
VCOM
110
L2500EA