Kohler 38RCL Manual page 35

Residential/light commercial generator sets
Hide thumbs Also See for 38RCL:
Table of Contents

Advertisement

SiteTech Group
Voltage Regulator
Voltage Regulator
Voltage Regulator
Engine Timing
Engine Timing
Engine Timing
Engine Timing
Engine Timing
Genset Protection
Genset Protection
Genset Protection
Genset Protection
Genset Protection
Genset Protection
Engine Protection
Engine Protection
Engine Protection
Engine Protection
Engine Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
Generator Protection
* Read Only = Not adjustable
w Load management device (LCM, load shed kit, or RXT with combined interface/load management board).
[ Notes indicate applicability to genset or accessories. N/A = Not applicable to the models covered in this manual.
] See TT-1584 for more information about digital inputs and outputs.
Grayed rows are visible in SiteTech but do not apply to all models.
TP-6811 7/16
Parameter
Voltage Regulator Volts Per
Hertz Slope
Voltage Regulator Volts Per
Hertz Cut In Frequency
Voltage Regulator Gain
Engine Start Delay
Engine Cool Down Delay
Engine Crank On Delay
Engine Crank Pause Delay
Engine Number Of Crank Cycles
Genset Low Battery Voltage
Warning Delay
Genset High Battery Voltage
Warning Delay
Genset Low Battery Voltage
Warning Limit
Genset High Battery Voltage
Warning Limit
Genset Battery Low Cranking
Voltage Warning Delay
Genset Battery Low Cranking
Voltage Warning Limit
Engine Locked Rotor Shutdown
Delay
Genset Low Engine Speed
Shutdown Limit
Genset High Engine Speed
Shutdown Limit
Engine Low Oil Pressure
Warning Limit
Engine High Oil Pressure
Shutdown Limit
Loss Of AC Sensing Shutdown
Delay
Genset Low Voltage Shutdown
Delay
Genset High Voltage Shutdown
Delay
Genset Low Voltage Shutdown
Limit
Genset High Voltage Shutdown
Limit
Genset Short Term Low
Frequency Shutdown Delay
Genset Long Term Low
Frequency Shutdown Delay
Genset High Frequency
Shutdown Delay
Genset Low Frequency
Shutdown Limit
Genset High Frequency
Shutdown Limit
Adjustment
Range *
Units
%
1-- 10
Hz
42 -- 62
1 -- 255
s
0 -- 300
s
300 -- 600
s
10 -- 30
s
1 -- 60
1 -- 6
s
Read Only
s
Read Only
%
80 -- 100
%
110 -- 135
s
Read Only
%
Read Only
s
3
%
75 -- 95
%
No effect.
kPa
No effect.
kPa
No effect.
s
Read Only
s
Read Only
s
Read Only
%
Read Only
%
Read Only
s
Read Only
s
Read Only
s
Read Only
%
Read Only
%
Read Only
Default Set-
ting
Notes
[
4
59
16
0
300
15
15
3
90
10
100
125
6
60
3
85
N/A
N/A
N/A
3
10
2
80
120
10
60
10
90
110
Section 3 Controller
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

48rcl48rcla60rcl

Table of Contents