Toshiba e-STUDIO2010AC User Manual page 13

Sys board diagnosis tool
Hide thumbs Also See for e-STUDIO2010AC:
Table of Contents

Advertisement

TABLE 1 - Correspondence table when NG occurs
No.
Inspection item Inspection result
01 Board Type
02 CPU Clock
03 FROM
04
Main Memory
Size
05
Main Memory
R/W
06 FRAM R/W
07 RTC
08 PCIE ASIC0
09 PCIE ASIC1
10 NIC PCIE
11 Network
NG
NG
NG
NG
NG <2GB>
NG <4GB>
NG
NG
NG
NG
OK?
[Not detected]
NG [NIC VER]
NG
NG [MAC_I2C]
NG [MAC_NIC]
NG [MAC_I2C]
[MAC_NIC]
13
Correspondence
Replace the SYS board.
Replace the SYS board.
Replace the SYS board.
Step 1.Check the installation status of the
Main memory and reinstall it if necessary.
Step 2. Perform calibration of the Main
memory at the time of startup.
Step 3. Replace the Main memory.
Step 4. Replace the SYS Board.
Step 1. Check the installation status of the
Main memory and reinstall it if necessary.
Step 2. Perform calibration of the Main
memory at the time of startup.
Step 3. Replace the Main memory
Step 4. Replace the SYS board.
Step 1. Check the installation status of
the SRAM (FRAM) and reinstall it if
necessary.
Step 2. Replace the SRAM (FRAM)
Step 3. Replace the SYS board.
Replace the SYS board.
Replace the SYS board.
Check only machine installed the
DSDF unit
Step 1. Check the installation status of
the DSDF I/F board and reinstall it if
necessary.
Step 2. Replace the DSDF I/F board.
Step 3. Replace the SYS board.
Step 1. Update NIC Firmware.
Step 2. Replace the SYS board.
Replace the SYS board.
Replace the SYS board.
Replace the SYS board.
Replace the SYS board.

Hide quick links: