Troubleshooting; Table 5-1: Syn-Tech Iii P25 Portable Radio Error Messages - Midland Syn-Tech III P25 Service Manual

Vhf and uhf
Hide thumbs Also See for Syn-Tech III P25:
Table of Contents

Advertisement

5

TROUBLESHOOTING

Syn-Tech III P25 Portable Radio Error Messages are given in Table 5-1:

Table 5-1: Syn-Tech III P25 Portable Radio Error Messages

ERROR
CAUSE
MESSAGE
ERROR 201
Is displayed when an error has been
found in the external RAM.
ERROR 202
Is displayed when an error has been
found in the audio processor
ERROR 203
Unknown hardware version
ERROR 302
Is displayed if the microcontroller cannot
connect with the DSP hardware.
ERROR 303
Is displayed when a CRC error has been
found in the DSP software.
ERROR 304
Is
has been found during DSP RAM control.
ERROR 305
Wrong DSP software may have been
loaded
ERROR 306
Wrong DSP software may have been
loaded.
ERROR 309
Means that there is problem in the
base band codec on the DSP board.
ERROR 310
Means that there is problem with the
audio codec on the DSP board.
ERROR 311
Means that there is problem with the
base band codec or audio codec on the
DSP board.
ERROR 312
Unsuitable DSP firmware
ERROR 313
No TX audio detected by DSP
ERROR 502
Is displayed if the DSP software hasn't
been installed.
displayed
when
an
SYN-TECH III P25 PORTABLE RADIO
SOLUTION
Change the RF & Control Board
Reload firmware
Return to factory
Check if the digital board is firmly fitted on the
RF & Control Board
Firmware must be reloaded.
error
Change the digital board.
Firmware must be reloaded.
Firmware must be reloaded.
Change the digital board.
Change the digital board.
Change the digital board.
Reload firmware
Replace DSP
Firmware must be reloaded
5-1