  • Page 1 INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part # A-03-331 | © 2012 Pentair Ltd. | 11/19/12...
  • Page 2: Installation

    SECTION 2 ITEM 1080 DATED NOVEMBER 2012 1080 SERIES SUPERCEDES MAY 2010 INTRODUCTION: INSTALLATION: Aurora heat exchangers are designed for highest efficiency 1. In selecting a location for the heat exchanger, provide and trouble-free service, based on many years of technical sufficient clearance at the head end of the exchanger to and operational research.
  • Page 3 SECTION 2 ITEM 1080 DATED NOVEMBER 2012 1080 SERIES SUPERCEDES MAY 2010 14. Quick-opening and closing valves controlling fluids to When this hammer effect has occurred in the shell of an or from an exchanger may cause water hammer, and care exchanger, the damage pattern is quite regular.
  • Page 4: Cleaning Precautions

    SECTION 2 ITEM 1080 DATED NOVEMBER 2012 1080 SERIES SUPERCEDES MAY 2010 (d) Removal of various scales and foreign material by 8. SPARE AND REPLACEMENT PARTS: Spare or replacement parts may be obtained for Aurora heat chemical cleaning is now being extensively practiced. Certain qualified organizations will check the nature exchangers by reference to the part required and to the of the deposits to be removed, furnish proper acid...
  • Page 5 SECTION 2 ITEM 1080 DATED NOVEMBER 2012 1080 SERIES SUPERCEDES MAY 2010 TYPICAL INSTALLATION OF 1080-ST HEAT CAUTION EXCHANGER SHOWING RECOMMENDED METHOD OF INSTALLING CONVERTERS WITH AURORA AIR CONTROL SYSTEM: Steam hammer can cause serious damage to the tubes of any heat exchanger. A careful consideration of the To establish air control in converter or heat exchanger following points before an installation is made can installations, a pipe mounted air eliminator is installed as...
  • Page 6 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 7 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 8: Warranty

    WARRANTY Seller warrants equipment (and its component parts) of its own manufacture against defects in materials and workmanship under normal use and service for one (1) year from the date of installation or start-up, or for eighteen (18) months after the date of shipment, whichever occurs first.