7
|
Unit installation

7.3.6 To install the discharge grille

7.4 Mounting the indoor unit

7.4.1 About mounting the indoor unit

Installer reference guide
88
a
2 Remove the burrs, and paint the edges and areas around the edges using
repair paint to prevent rusting.
NOTICE
When making knockout holes, do NOT damage the casing and underlying piping.
1 Insert the hooks. To prevent breaking the hooks:
▪ First insert the bottom hooks (2×).
▪ Then insert the top hooks (2×).
2 Insert and fix the screws (4×)(delivered as accessory).
1
2
4 N • m
T25
When
You have to mount the outdoor and indoor unit before you can connect the
refrigerant and water piping.
2
1
ERLA11~16DAV3+W1 + EBSH/X(B)11+16P30+50DF
Daikin Altherma 3 R ECH₂O
4P663482-1A – 2021.11