3.
Prepare for necessary the shims from converted shims information (P1 to P3), and attach them as shown in Fig.
2-4-2.
Note
Tightening order of screws: P2, P3, P1
P1
P2
Fig. 2-4-2
2-4-2.
Photographic Resolving Power Check
Equipment and Tools
• Resolving power check chart
Note
Prepare the resolving power check chart as following procedure.
1.
Download the "Focus-Chart_A3.pdf".
2.
Print "Focus-Chart_A3.pdf" at 100% size.
Preparations
1.
Set the unit as shown below.
Shooting mood: Still image
Image quality, size: 4:3 L (15.4M)
Iris: Manual (F1.8)
Self- timer: ON
Zoom: Wide end
2.
Set the resolving power check chart at shooting distance of 530±20 mm from the filter frame front of the unit.
3.
Focus to make the chart aligned equally in all directions at wide end.
FDR-AX30/FDR-AX33/FDR-AXP33/FDR-AXP35
P3
533 mm
Fig. 2-4-3
2-7