Dryer Exhausting Information – Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be
used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house
vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY
in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4"
diameter can be maintained throughout the entire length of the transition duct. Please see installation
instruction packed with your dryer for complete instructions when using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house
floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture
could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen
exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc.
The wall cap must also be located at least 12" above the ground or any other obstruction with the
opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
For answers to your Monogram,
GE Profile
®
GE
appliance questions, visit our website at
®
geappliances.com or call GE Answer Center
service, 800.626.2000.
or
®
A
Number
4
of
B
90°
turns
2-1/2
0
1
Frontload dryers:
2
DSXH43EF/GF
3
DSXH47EG/GG
4
Specification Revised 1/10
Best performance
Maximum length of
4" dia. rigid metal duct
Exhaust hood type
B
A
2-1/2"
4" opening
opening
60 ft.
48 ft.
52 ft.
40 ft.
44 ft.
32 ft.
32 ft.
24 ft.
28 ft.
16 ft.
360425