GE DSKS333E Dimensions And Installation Information page 2

Stationary dryer

Advertisement

DSKS333EC
GE Spacemaker
Stationary Dryer
®
Dimensions and Installation Information (in inches)
A
A
4
Number
B
of
90°
Domestic
2-1/2
turns
dryer models
DSKS433EB
0
DSKS333EC
1
DSKP333EC
2
WSM2780H
3
0
1
2
WSM2700H
3
0
WSM2420D*
1
WSM2480D*
2
*Foil ducting not allowed
For answers to your Monogram,
GE Profile
®
GE
appliance questions, visit our website at
®
geappliances.com or call GE Answer Center
service, 800.626.2000.
Best performance
Maximum length of 4"
dia. rigid metal duct
Exhaust hood type
A
B
4"
2-1/2"
opening
opening
46 ft.
37 ft.
38 ft.
30 ft.
31 ft.
22 ft.
24 ft.
15 ft.
56 ft.
42 ft.
46 ft.
36 ft.
34 ft.
28 ft.
32 ft.
18 ft.
43 ft.
36 ft.
33 ft.
26 ft.
23 ft.
16 ft.
or
®
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal
(semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be
necessary to connect the dryer to the house vent using a flexible metal (foil-type)
duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations
where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a
4" diameter can be maintained throughout the entire length of the transition duct.
Please see installation instruction packed with your dryer for complete instructions
when using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to
the side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be
tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should
be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust
into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,
bird nesting, etc. The wall cap must also be located at least 12" above the ground or
any other obstruction with the opening pointed down.