STEP 4
Connect both dryers to power supply. (See ELECTRICAL
CONNECTION INFORMATION section of this instruction.)
STEP 5
Connect both dryers to external exhaust. (See EXHAUST
INFORMATION of this instruction.)
STEP 6
Hook both chains from upper unit to appropriate wall hooks
taking up any slack.
STEP 7
Adjust all 4 levelling legs. Dryer must be levelled and rest
firmly on all 4 levelling legs.
Alternate Method for Installation of Wall Hooks
STEP 1
If wall studs are not correctly spaced or centered behind upper unit, it
may be necessary to attach a horizontal 2" x 4" board to the existing
wall.
STEP 2
Attach wall hooks in approximate position of two chains of upper unit so
each chain pulls straight back to wall.
NOTE: If wall is concrete or block, drill holes and use appropriate wall
anchors. The final construction must withstand a pull of 200 lbs.
CONNECTING DRYER USING 3-WIRE CONNECTION
• Remove the cover near the power cord entry hole.
• Install 3/4" UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
• Connect two HOT lines to outer screws (L1 & L2) of terminal block.
• Connect NEUTRAL (white) line to center screw (N) of terminal block.
• Tighten all terminal block screws firmly.
• Properly secure power supply cable to strain relief.
• Reinstall the cover.
CAUTION, FOR PERSONAL SAFETY:
THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
Grounding:
• If local codes permit, be sure ground strap is
connected to neutral (centre terminal of block and
to ground screw on rear frame).
• If local codes do not permit frame of dryer to be
grounded to neutral, remove and discard ground
strap. The frame must be grounded by attaching a
ground wire (not supplied) to the green grounding
screw on rear of dryer and to a grounded metal
cold water pipe or other established ground.
WARNING: NEVER LEAVE THE TERMINAL BLOCK WITHOUT THE COVER.
INSTALLATION (continued)
GROUND
TO GREEN
GROUND
SCREW ON
CABINET
REAR
IF REQUIRED, INSTALL
EXTERNAL GROUND (NOT
PROVIDED) TO GROUNDED
METAL COLD WATER PIPE OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
STEP 8
GROUND
STRAP
GREEN
GROUND
SCREW
strain relief
bracket
HOT
NEUTRAL
(white)
HOT
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR
120/240V 30A POWER SUPPLY CORD KIT
MARKED FOR USE WITH DRYERS &
PROVIDED WITH CLOSED LOOP OR SPADE
TERMINALS WITH UPTURNED ENDS (NOT
SUPPLIED).
3/4", UL
recognized
strain relief