Download Print this page
GE DDC4500T5WH Installation Instructions Manual
GE DDC4500T5WH Installation Instructions Manual

GE DDC4500T5WH Installation Instructions Manual

Commercial stacked gas dryer

Advertisement

Quick Links

10
- WARNING
RISK OF FIRE
• To reduce the risk of severe injury or death, follow all installation
instructions.
• Clothes dryer installation must be performed by a qualified installer.
• Install the clothes dryer according to these instructions and in accordance with local codes. In the absence of local codes,
installation must comply with National FuelGas Code,ANSIZ223.1/NFPA 5 4 or the CanadianNatural Gasand PropaneInstallation Code,
CSA B149.1.
•California Safe Drinking Water and Toxic Enforcement Act
This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects
or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas
appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot,
caused primarily
by
the incomplete combustion of natural gas or
LP
fuels. Properly adjusted dryers will minimize incomplete
combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.
• This dryer must be exhausted to the outdoors.
• Use only4" rigid metal ducting for exhaustingthe clothes dryerto the outdoors.
• DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-rigid or foil-type) duct is installed,
it must be UL listed and installed in accordance with these instructions and local codes. Flexible venting materials are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire.
• Do not install or store this appliance in any location where it could be exposed to water and or weather.
• Save these instructions. (Installers: Be sure to leave these instructions with the customer).
BEFORE YOU BEGIN
Reed these instructions completelg end cerefullg.
IMPORTANT-
Save these instructions for local inspector's use.
IMPORTANT-
Observe all governing codes and ordinances.
• Note to Instoller - Be sure to leave these instructions with the customer.
• Note to Customer- Keep these instructions with your Owner's Manual for future
reference
• Before the old dryer is removed from service or discarded, remove the dryer door.
• Inspect the dryer exhaust outlet and straighten the outlet walls if they are bent.
• Service information and the wiring diagram are located in the control console.
• Do not allow children on or in the appliance. Close supervision of children is
necessary when the appliance is used near children.
• Install the dryer where the temperature is above 50°Ffor satisfactory operation
of the dryer control system.
• Product failure due to improper installation is not covered under the Warranty.
Tools and Materials
You
Will Need
n Slip joint pliers, 8" pipe wrench and
10"adjustable wrenches (x2).
[] Screwdrivers (slotted or phillips head).
[] Chains (x2).
[] 2" x 4" studs.
[]Wall hooks.
[]/4" diameter rigid metal duct, duct
clamps, elbows and exhaust hood.
[] Flexible gas connecto[
[] Pipe compound.
[] Soap solution for leak detection.
[] Basic safety protection
such as safety
goggles, gloves and arm protection are
recommended.
- kWAR N IN G
Foryour safety the information
in this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage,
personal injury or death.
-Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
-WHAT TO DO IF YOU SMELLGAS
•Do not light any appliance.
• Do not touch any electrical switch; do not use any phone
in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
-Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
The ANSI Z21.5.1 standard requires the following safety
cautions be posted and displayed in a prominent
location:
a. Instructions to be followed in the event the user smells
gas. The information
to be posted shall be obtained
by
consulting with the local gas supplier.
b. This note:
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
IN THE COMMONWEALTH
OF MASSACHUSETTS
• This product must be instolled by e licensed plumber or
gos fitter.
• When using boll-tgpe gos shut-off velves, they shell be
the T-hendle tgpe.
• A flexible gos connector, when used, most not exceed 3
feet.
nrintedin Conodo
234D1582P010
31-16677
03-12
GE

Advertisement

loading

Summary of Contents for GE DDC4500T5WH

  • Page 1 - WARNING RISK OF FIRE • To reduce the risk of severe injury or death, follow all installation instructions. • Clothes dryer installation must be performed by a qualified installer. • Install the clothes dryer according to these instructions and in accordance with local codes. In the absence of local codes, installation must comply with National FuelGas Code,ANSIZ223.1/NFPA 5 4 or the CanadianNatural Gasand PropaneInstallation Code, CSA B149.1.
  • Page 2: Installation Instructions

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and i in. rear. Consideration must be given to provide adequate clearance for operation and service. Preparing the Installation Site and Unpacking the Dryer 1.
  • Page 3: Installation

    Installation Instructions Alternate Method for Installation of Wall Hooks STEP1 WALL STUDS If wall studs ore not correctly spaced or centered behind upper unit, it may be necessary to attach a horizontal 2" x 4" board to the existing wall. STEP2 Attach wall hooks in approximate position of two chains of upper unit so each chain pulls straight back to wall.
  • Page 4 Installation Instructions I_ RECONNECTING Listed connector ANSI Z2]_.24 / CSA 6.!0 APPLYPIPECOMPOUND TO ALL MALETHREADS. 1/8" NPT PIPE PLUGFOR NEWMETAL FLEXIBLE GAS INLETPRESSURE LINECONNECTOR ADAPTER SHUT-OFF 3/8" NPT VALVE ELBOW PIPESIZE ITEMSNOT SUPPLIED AT LEAST1/2" NOTE:The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location.
  • Page 5 Installation Instructions I-_ EXHAUST INFORMATION [] EXHAUST CONNECTION WARNING - BEFORE P ERFORMING - WARNING - TO REDUCE THE RISK THIS EXHAUST INSTALLATION, BE SURE TO OF FIRE OR PERSONAL INJURY: DISCONNECT THEDRYERFROMITSELECTRICAL • This clothes dryer must be exhausted to the outdoors. SUPPLY.PROTECT YOUR HANDS AND ARMS •...
  • Page 6 Installation Instructions 161EXHAUST CONNECTION CONT. I-7-1 ALCOVE OR CLOSET INSTALLATION THIS DRYER COMES READY FOR REAR •If your dryer is approved for installation in an alcove or EXHAUSTING. IF SPACE IS LIMITED, USE closet, it will be stated on a label on the dryer back. THESE INSTRUCTIONS TO EXHAUST •...
  • Page 7 Installation Instructions ADJUSTING FOR ELEVATION [_ELECTRICAL CONNECTION INFORMATION • Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or WARNING - TO REDUCE THE RISK below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings OF FIRE, ELECTRICAL SHOCK, AND should be reduced at a rate of 4 percent for each 1000 ft.
  • Page 8 Installation Instructions...